Literature DB >> 10469491

Polarization sensing of fluorophores in tissues for drug compliance monitoring.

Z Gryczynski1, O O Abugo, J R Lakowicz.   

Abstract

We used a new method, polarization sensing, to monitor the concentration of the fluorophore rhodamine 800 in an intralipid suspension and in chicken tissue. Rhodamine 800 (Rh800) could be excited at 648 nm using a laser pointer. We developed a simple device for measuring the combined emission from a highly polarized reference film and the unpolarized or orthogonally polarized emission of Rh800 from the scattering intralipid or tissue. The concentration of Rh800 in this medium was revealed by large changes in the polarization (P) with values of P ranging from 0.8 to -0.9. It is possible to vary the sensitive Rh800 concentration range by variation of the detected emission wavelengths, orientation of the excitation polarizer, or fluorophore concentration in the reference film. Polarization sensing of fluorophores in tissue requires only steady-state detection, and can be accomplished with simple and/or portable electronics. Such devices may find use in electronic detection of ingested medicines based on transdermal detection of nontoxic long-wavelength fluorophores. Copyright 1999 Academic Press.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10469491      PMCID: PMC6938722          DOI: 10.1006/abio.1999.4213

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  11 in total

1.  Selective laser photocoagulation of blood vessels in a hamster skin flap model using a specific ICG formulation.

Authors:  S Mordon; T Desmettre; J M Devoisselle; V Mitchell
Journal:  Lasers Surg Med       Date:  1997       Impact factor: 4.025

Review 2.  Determination of plasma volume and total blood volume using indocyanine green: a short review.

Authors:  S Henschen; M W Busse; S Zisowsky; B Panning
Journal:  J Med       Date:  1993

3.  Assessing medication adherence by pill count and electronic monitoring in the African American Study of Kidney Disease and Hypertension (AASK) Pilot Study.

Authors:  J Y Lee; J W Kusek; P G Greene; S Bernhard; K Norris; D Smith; B Wilkening; J T Wright
Journal:  Am J Hypertens       Date:  1996-08       Impact factor: 2.689

Review 4.  Compliance, electronic monitoring and antihypertensive drugs.

Authors:  J M Mallion; J P Baguet; J P Siche; F Tremel; R de Gaudemaris
Journal:  J Hypertens Suppl       Date:  1998-01

5.  Burn depth estimation by use of indocyanine green fluorescence: initial human trial.

Authors:  R L Sheridan; K T Schomaker; L C Lucchina; J Hurley; L M Yin; R G Tompkins; M Jerath; A Torri; K W Greaves; D P Bua
Journal:  J Burn Care Rehabil       Date:  1995 Nov-Dec

6.  Hepatic removal of two fractions of indocyanine green after bolus injection in anesthetized pigs.

Authors:  P Ott; S Keiding; A H Johnsen; L Bass
Journal:  Am J Physiol       Date:  1994-06

Review 7.  Tuberculosis--fighting a losing battle?

Authors:  K K Tan
Journal:  Singapore Med J       Date:  1995-04       Impact factor: 1.858

8.  Adherence to oral tamoxifen: a comparison of patient self-report, pill counts, and microelectronic monitoring.

Authors:  D M Waterhouse; K A Calzone; C Mele; D E Brenner
Journal:  J Clin Oncol       Date:  1993-06       Impact factor: 44.544

9.  Intravital detection of skin capillary aneurysms by videomicroscopy with indocyanine green in patients with progressive systemic sclerosis and related disorders.

Authors:  A Bollinger; B Saesseli; U Hoffmann; U K Franzeck
Journal:  Circulation       Date:  1991-02       Impact factor: 29.690

10.  Yield of fluorescence from indocyanine green in plasma and flowing blood.

Authors:  P R van den Biesen; F H Jongsma; G J Tangelder; D W Slaaf
Journal:  Ann Biomed Eng       Date:  1995 Jul-Aug       Impact factor: 3.934

View more
  2 in total

1.  Fluorescence properties of albumin blue 633 and 670 in plasma and whole blood.

Authors:  O O Abugo; P Herman; J R Lakowicz
Journal:  J Biomed Opt       Date:  2001-07       Impact factor: 3.170

2.  Enhanced fluorescence anisotropy assay for human cardiac troponin I and T detection.

Authors:  Yanling Qiao; Hongmin Tang; Gerhard R Munske; Prashanta Dutta; Cornelius F Ivory; Wen-Ji Dong
Journal:  J Fluoresc       Date:  2011-06-07       Impact factor: 2.217

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.