Literature DB >> 10468359

Viscoelasticity modulates resonance in the terminal aortic circulation.

R Burattini1, S Natalucci, K B Campbell.   

Abstract

We used an inertance-viscoelastic windkessel model (IVW) to interpret aortic impedance patterns as seen in the terminal aortic circulation of the dog, and to explain evident oscillatory phenomena in flow measurements. This IVW model consists of an inertance, L, connected in series with a viscoelastic windkessel (VW) where the peripheral resistance, Rp, is connected in parallel with a Voigt cell (a resistor, Rd, in series with a capacitor, C) to account for viscoelasticity. Pressure and flow measurements were taken from the terminal aorta, just downstream of the origin of renal arteries, in three anaesthetised open-chest dogs, under a variety of haemodynamic conditions induced by administering a vasoconstrictor agent (methoxamine) and a vasodilator (sodium nitroprusside). Mean pressure ranged from 40 to 140 mm Hg. The resistance Rp was calculated as the ratio of mean pressure to mean flow. Parameters L, C and Rd were estimated by fitting measured to model predicted flow waves. We found that prominent oscillations observed in flow waves, from midsystole to diastole, are related to resonance that occurs at a frequency, f(o), where reactance of inertance of blood motion matches the reactance of arterial compliance. Estimates of f(o) increased from 2.4 to 10 Hz with increasing pressure and showed a correlation with values of static elastic moduli plotted against mean pressure of dogs' peripheral arteries previously reported by others. Viscous losses, Rd, of arterial wall motion limited the amplitude of resonance peak. We conclude that viscoelasticity, rather than pure elasticity, is a key issue to interpret terminal aortic impedance as it relates to resonance.

Entities:  

Mesh:

Year:  1999        PMID: 10468359     DOI: 10.1016/s1350-4533(99)00041-7

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

Review 1.  The arterial Windkessel.

Authors:  Nico Westerhof; Jan-Willem Lankhaar; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

2.  Assessment of Fractional-Order Arterial Windkessel as a Model of Aortic Input Impedance.

Authors:  Mohamed A Bahloul; Taous-Meriem Laleg-Kirati
Journal:  IEEE Open J Eng Med Biol       Date:  2020-04-22

3.  Inadequacy of Augmentation Index for Monitoring Arterial Stiffness: Comparison with Arterial Compliance and Other Hemodynamic Variables.

Authors:  Mehmet Kaya; Vignesh Balasubramanian; John K-J Li
Journal:  Cardiovasc Eng Technol       Date:  2022-01-31       Impact factor: 2.305

  3 in total