| Literature DB >> 10467307 |
D L Buckley1, J D Bui, M I Phillips, S J Blackband.
Abstract
T(1)-weighted NMR imaging of the isolated perfused rat hippo-campal slice was used to estimate cell volume fraction. Eight brain slices were studied in artificial cerebrospinal fluid (aCSF) using a 600 MHz narrow bore spectrometer and a home built perfusion chamber. Cell volume fraction was calculated as 1 - f(ECS), where f(ECS) is the distribution volume of gadodiamide in the slice. This was determined by measuring the T(1) of the slice before and after perfusion with gadodiamde. A mean cell volume fraction of 0.66 +/- 0. 04 was estimated. The addition of 60 mM mannitol to three of the brain slices produced a 26% decrease in the cell volume fraction. The technique affords a simple means of estimating cell volume fraction and can be extended to produce images reflecting cell density. Magn Reson Med 42:603-607, 1999. Copyright 1999 Wiley-Liss, Inc.Entities:
Mesh:
Substances:
Year: 1999 PMID: 10467307 DOI: 10.1002/(sici)1522-2594(199909)42:3<603::aid-mrm25>3.0.co;2-q