Literature DB >> 10466484

Sudden death in recipients of transvenous implantable cardioverter defibrillator systems: terminal events, predictors, and potential mechanisms.

L A Pires1, M L Hull, C L Nino, L M May, J R Ganji.   

Abstract

INTRODUCTION: Transvenous implantable cardioverter defibrillator (ICD) systems are very effective in preventing sudden death; however, little is known about terminal events and potential causes and mechanisms of sudden death in recipients of these devices. METHODS AND
RESULTS: We analyzed 74 cases of sudden death among patients enrolled in several clinical investigations of transvenous ICD systems. Eighty-one percent were men (mean age 68+/-10 years), 86% had coronary artery disease, mean left ventricular ejection fraction was 0.27+/-0.11, and two thirds presented with sustained ventricular tachycardia. The final event was witnessed in 65 patients (81%). Based on reported ICD shocks, documented rhythm, and/or postmortem device data, sudden death was deemed tachyarrhythmic in 49 cases (66%), nontachyarrhythmic in 12 (16%), and indeterminate in the remaining 13 (18%). Multivariate analysis of several clinical and nonclinical factors found advanced age (> 65 years, P = 0.03, odds ratio [OR] 1.75, 95 % confidence interval [CI] 1.05 to 2.92), reduced left ventricular ejection fraction (< 0.35, P < 0.01, OR 3.51, CI 1.66 to 7.40), and having antibradycardia pacing ICDs (P = 0.02, OR 5.26, CI 1.37 to 20.0) to be independent predictors of sudden death. One or more predisposing factors and/or potential causes of sudden death were identified in 21 patients (28%).
CONCLUSION: In this select group of transvenous ICD recipients, (1) sudden death was associated with ventricular tachycardia/ventricular fibrillation in at least two thirds of cases, (2) nearly one third of patients had one or more factors, some device related, that could have been associated with sudden death, and (3) death ensued despite appropriate ICD therapies and, in many cases, external resuscitation, suggesting acute adverse events as common terminal factors.

Entities:  

Mesh:

Year:  1999        PMID: 10466484     DOI: 10.1111/j.1540-8167.1999.tb00276.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  6 in total

1.  [Is intraoperative ICD-testing still necessary?].

Authors:  C Mewis; H-R Neuberger; A Buob
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-06

2.  Sports participation in patients with implantable cardioverter-defibrillators.

Authors:  R Lampert; B Olshansky
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-06

3.  Azygos vein lead implantation for high defibrillation thresholds in implantable cardioverter defibrillator placement.

Authors:  Naga Va Kommuri; Sri Lakshmi S Kollepara; E Saulitis; Ma Siddiqui
Journal:  Indian Pacing Electrophysiol J       Date:  2010-01-07

4.  Determination of time of death by blinded post-mortem interrogation of cardiac implantable electrical devices.

Authors:  Korbinian Lackermair; Florian Fischer; Johannes Manhart; Eva Scheurer; Matthias Graw; Diana Boy; Claudia Lenz; Bonnie Hartrampf; Antonia Kellnar; Lauren Sams; Heidi Estner; Stephanie Fichtner
Journal:  Sci Rep       Date:  2022-05-17       Impact factor: 4.379

5.  Defibrillation testing of the implantable cardioverter defibrillator: when, how, and by whom?

Authors:  Luis A Pires
Journal:  Indian Pacing Electrophysiol J       Date:  2007-08-01

Review 6.  The incidence and impact of implantable cardioverter defibrillator shocks in the last phase of life: An integrated review.

Authors:  Rik Stoevelaar; Arianne Brinkman-Stoppelenburg; Rohit E Bhagwandien; Rozemarijn L van Bruchem-Visser; Dominic Amj Theuns; Agnes van der Heide; Judith Ac Rietjens
Journal:  Eur J Cardiovasc Nurs       Date:  2018-05-18       Impact factor: 3.908

  6 in total