Assessing lung deposition of inhaled medications. Consensus statement from a workshop of the British Association for Lung Research, held at the Institute of Biology, London, U.K. on 17 April 1998.

N J Snell1, D Ganderton.   

Abstract

In vitro measurements of aerosol fine particle fraction (FPF) using particle-sizing apparatus (e.g. the twin impinger, multi-stage liquid impingers, cascade impactors) have a key role to play in the development of new pharmaceutical products and in quality control. However, use of in vitro methodology to attempt to predict lung deposition in vivo is of limited value due, in part, to the inability of current apparatus to mimic upper and lower airway anatomy satisfactorily. Estimates of FPF based on cut-off points ranging from 5-7 microns generally overestimate lung deposition as measured in vivo by gamma scintigraphy. We recommend that: 1. multistage apparatus (minimum five stages) be used to characterize particle size distribution adequately, over the range 0.5-5.0 microns; 2. where possible, measurements should be made at a range of rates and profiles of flow reflecting those likely to be generated using the inhalation device in clinical practice (including use by young and elderly patients with varying degrees of airflow obstruction); 3. encouragement should be given to the further development, standardization, and validation of apparatus with a 'throat' which more closely resembles the human oropharynx and larynx. Pharmacokinetic methods can give a good estimate of total, but not regional, lung deposition, with drugs which are either not absorbed via the gastrointestinal tract, or whose absorption can be blocked by co-administration of charcoal, thus avoiding confounding by absorption of drug substance deposited in the oropharynx and subsequently swallowed. Techniques which rely on evaluation of a timed fractional output of drug substance in the urine are susceptible to the inherent variability of rate of absorption across the respiratory epithelium. We recommend that consideration should be given to the further refinement and validation of PK methods which would more clearly identify the fractional dose deposited in the lung. Lung-imaging methodology, e.g. gamma scintigraphy, employing formulations radiolabelled with gamma-ray-emitting radionuclides such as 99mTc, can measure total lung deposition and oropharyngeal deposition, provided that the radiolabelling process is appropriately validated and suitable corrections are made for attenuation of gamma rays by body tissues. An estimate of regional lung deposition can be made by drawing 'regions of interest' on the scintigraphic image; the precision of this measure is limited by the two-dimensional (2-D) nature of most images which mean that there is an overlay of structures of interest (alveoli, small and large airways), which is most marked centrally. Three-dimensional (3-D) imaging techniques (e.g. single photon emission computed tomography, SPECT, and positron emission tomography, PET) have the potential to give more detailed data on regional lung deposition, but are currently more expensive, employ higher radiation doses, and are less well validated than 2-D (planar) imaging. We consider that, of the available imaging modalities, planar gamma scintigraphy represents current best practice for the assessment of lung deposition from inhaler devices where regional differences may be important. The methodology should be optimized by the adoption of generally accepted standards for radiolabelling, imaging, attenuation correction, and interpretation. It is important that deposition in all sites (device, oropharynx, lungs, stomach) should be quantified. Consideration should be given to refining the concept of regions of interest to coincide more closely with anatomical lung structures. Statistical methods to compare the size distributions of drug and radiolabel in validation experiments should be developed. In the longer term it is envisaged that three-dimensional imaging may play a more important part in evaluating lung deposition; an optimal three-dimensional anatomical model of lung zones of interest needs to be developed.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10464864     DOI: 10.1016/s0954-6111(99)90302-5

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  20 in total

Review 1.  Can lung deposition data act as a surrogate for the clinical response to inhaled asthma drugs?

Authors:  S P Newman
Journal:  Br J Clin Pharmacol       Date:  2000-06       Impact factor: 4.335

2.  Methods to determine lung distribution of inhaled drugs - could gamma scintigraphy be the gold standard?

Authors:  H Chrystyn
Journal:  Br J Clin Pharmacol       Date:  2000-06       Impact factor: 4.335

3.  Lung distribution of inhaled drugs.

Authors:  S P Newman
Journal:  Br J Clin Pharmacol       Date:  2001-12       Impact factor: 4.335

Review 4.  Discriminating measures of bronchodilator drug efficacy and potency.

Authors:  H Buck; M Parry-Billings
Journal:  Br J Clin Pharmacol       Date:  2001-09       Impact factor: 4.335

Review 5.  Methods to identify drug deposition in the lungs following inhalation.

Authors:  H Chrystyn
Journal:  Br J Clin Pharmacol       Date:  2001-04       Impact factor: 4.335

Review 6.  Deposition and effects of inhaled corticosteroids.

Authors:  Stephen P Newman
Journal:  Clin Pharmacokinet       Date:  2003       Impact factor: 6.447

7.  Pharmacokinetics of Colistin Methansulphonate (CMS) and Colistin after CMS Nebulisation in Baboon Monkeys.

Authors:  Sandrine Marchand; Salim Bouchene; Michèle de Monte; Laurent Guilleminault; Jérôme Montharu; Maria Cabrera; Nicolas Grégoire; Patrice Gobin; Patrice Diot; William Couet; Laurent Vecellio
Journal:  Pharm Res       Date:  2015-06-04       Impact factor: 4.200

8.  Introduction: Aerosol delivery of orally inhaled agents.

Authors:  Timothy E Corcoran; Sunalene G Devadason; Philip J Kuehl
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2012-12       Impact factor: 2.849

Review 9.  Spacer devices for metered dose inhalers.

Authors:  Stephen P Newman
Journal:  Clin Pharmacokinet       Date:  2004       Impact factor: 6.447

10.  Aerosol generation by metered-dose inhalers containing dimethyl ether/propane inverse microemulsions.

Authors:  Mark L Sommerville; Anthony J Hickey
Journal:  AAPS PharmSciTech       Date:  2003-11-26       Impact factor: 3.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.