OBJECTIVE: To determine the chemical stability of various mitomycin C (MMC) solutions used in glaucoma filtering surgery.
METHODS: A survey of the MMC solutions currently in use in 21 hospitals (11 in Canada, 10 in the United States) was conducted. A comparative study of the chemical stability of five different representative solutions was performed. The effects of buffer and storage variables on the chemical breakdown of MMC in the solutions were studied by means of high-performance liquid chromatography (HPLC).
RESULTS: The survey revealed 33 different variations (including recipes and storage conditions) in the preparation of MMC solutions. Although the majority of the hospitals (15 of 21; 72%) were preparing stable solutions, six of the hospitals (28%) were preparing potentially unstable solutions. The stability of the solutions varied in a nonuniform manner when stored at different temperatures in different buffers.
CONCLUSION: The lack of standardization and quality control of MMC solutions used in filtering surgery allows for the possibility of hospitals preparing unstable solutions.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10464732

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  2 in total

1.  Solubilization and Stability of Mitomycin C Solutions Prepared for Intravesical Administration.

Authors:  Alan L Myers; Yan-Ping Zhang; Jitesh D Kawedia; Ximin Zhou; Stacey M Sobocinski; Michael J Metcalfe; Mark A Kramer; Colin P N Dinney; Ashish M Kamat
Journal:  Drugs R D       Date:  2017-06

Review 2.  A review of the efficacy of mitomycin C in glaucoma filtration surgery.

Authors:  Ahmed Al Habash; Leyla Ali Aljasim; Ohoud Owaidhah; Deepak P Edward
Journal:  Clin Ophthalmol       Date:  2015-10-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.