Literature DB >> 10463539

Applications for the new electrochemiluminescent (ECL) and biosensor technologies.

S J Swanson1, S J Jacobs, D Mytych, C Shah, S R Indelicato, R W Bordens.   

Abstract

Biosensor and electrochemiluminescent (ECL) assays are replacing enzyme-linked immunosorbent assays (ELISAs) at Schering-Plough as immunoassays of choice to monitor cytokine levels and detect anti-cytokine antibody responses during cytokine therapy. These new assays provide increased sensitivity and a better correlation with biological assays. Biosensor assays using the BIACORE 2000 (BIACORE, Uppsala, Sweden) are being adopted to support preclinical and clinical trials for the detection of antibodies capable of binding to IL-10 and IL-4. Significant advantages when using a biosensor assay are that real-time and label-free detection permit increased throughput and direct detection of binding interactions which enables detection of low affinity antibodies that are not detected by ELISA. The ECL assays using the ORIGEN Analyser (IGEN, Gaithersburg, MD) that we have implemented to replace existing ELISAs for quantification of serum IL-10 and serum interferon alfa levels are more sensitive and less subject to matrix effects. Data obtained during the validation of these assays are described.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10463539

Source DB:  PubMed          Journal:  Dev Biol Stand        ISSN: 0301-5149


  5 in total

Review 1.  Progress in the use of biological assays during the development of biotechnology products.

Authors:  A R Mire-Sluis
Journal:  Pharm Res       Date:  2001-09       Impact factor: 4.200

Review 2.  Blood-based diagnostics of traumatic brain injuries.

Authors:  Stefania Mondello; Uwe Muller; Andreas Jeromin; Jackson Streeter; Ronald L Hayes; Kevin K W Wang
Journal:  Expert Rev Mol Diagn       Date:  2011-01       Impact factor: 5.225

Review 3.  Current methods for detecting antibodies against erythropoietin and other recombinant proteins.

Authors:  Robin Thorpe; Steven J Swanson
Journal:  Clin Diagn Lab Immunol       Date:  2005-01

4.  Optimization and validation of a multiplex, electrochemiluminescence-based detection assay for the quantitation of immunoglobulin G serotype-specific antipneumococcal antibodies in human serum.

Authors:  Rocio D Marchese; Derek Puchalski; Pamela Miller; Joseph Antonello; Olivia Hammond; Tina Green; Leonard J Rubinstein; Michael J Caulfield; Daniel Sikkema
Journal:  Clin Vaccine Immunol       Date:  2009-01-21

5.  Evaluation of the safety and immunogenicity of the oral inactivated multivalent enterotoxigenic Escherichia coli vaccine ETVAX in Bangladeshi adults in a double-blind, randomized, placebo-controlled Phase I trial using electrochemiluminescence and ELISA assays for immunogenicity analyses.

Authors:  Marjahan Akhtar; Mohiul I Chowdhury; Taufiqur R Bhuiyan; Joanna Kaim; Tasnuva Ahmed; Tanzeem A Rafique; Arifuzzaman Khan; Sadia I A Rahman; Farhana Khanam; Yasmin A Begum; Mir Z Sharif; Laila N Islam; Nils Carlin; Nicole Maier; Alan Fix; Thomas F Wierzba; Richard I Walker; A Louis Bourgeois; Ann-Mari Svennerholm; Firdausi Qadri; Anna Lundgren
Journal:  Vaccine       Date:  2018-11-22       Impact factor: 3.641