Experience with a low profile bipolar, active fixation pacing lead in pediatric patients.

R M Campbell1, A A Raviele, E J Hulse, D O Auld, G J McRae, V K Tam, K R Kanter.   

Abstract

Continued miniaturization of permanent pacing systems has promoted use of this technology in younger and smaller pediatric patients. Intermedics ThinLine 438-10 active fixation pacing leads (4.5 Fr lead body) were implanted in 26 patients (17 males/9 females; 9.9 +/- 6.9 years). Twenty of 26 patients received dual chamber systems, 6 of 26 patients single lead systems. Each patient has been followed 3 months. Pacemaker analysis at implant and 6 months later evaluated pulse width thresholds at 2.5 V (atrial 0.07 +/- 0.02 vs 0.13 +/- 0.02 ms [P = 0.01]; ventricular 0.08 +/- 0.04 ms vs 0.20 +/- 0.04 ms [P = 0.01]); sensing thresholds (atrial 4.1 +/- 0.41 mV vs 4.0 +/- 4.2 mV [P = NS]; ventricular 9.7 +/- 0.72 vs 9.3 +/- 0.94 mV [P = NS]); and impedance (atrial 345 +/- 12 vs 370 +/- 120 O [P = 0.04]; ventricular 412 +/- 17 vs 458 +/- 190 O [P < 0.01]). One volt lead failed with exit block at approximately 6 weeks. The youngest (9 months to 5 years) and smallest (6.5-18.0 kg) ten patients have each shown by venography to have at least mild venous stenosis at the lead(s) insertion site; five patients demonstrated collateral formation around asymptomatic obstruction, with no thrombus formation. The Intermedics 438-10 ThinLine pacing lead has demonstrated good and stable early postimplant electrical parameters. Angiographic evaluation in our smaller patients has shown evidence for asymptomatic venous obstruction.

Entities:  

Mesh:

Year:  1999        PMID: 10461290     DOI: 10.1111/j.1540-8159.1999.tb00594.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Special problems of pacing in children.

Authors:  Herwig Antretter; Joshua Colvin; Ulli Schweigmann; Herbert Hangler; Daniel Hofer; Karin Dunst; Josef Margreiter; Guenther Laufer
Journal:  Indian Pacing Electrophysiol J       Date:  2003-01-01

2.  Long term follow up of long QT syndrome treated by overdrive pacing.

Authors:  B Campanelli; J M Chaudron
Journal:  Heart       Date:  2001-11       Impact factor: 5.994

3.  Case series of late lead dislodgement of Medtronic SelectSecure 3830 pacing leads in growing paediatric patients.

Authors:  Li Yen Ng; Sarah Gallagher; Kevin P Walsh
Journal:  Eur Heart J Case Rep       Date:  2021-01-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.