Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study.

S Sivanesan1, T V How, R A Black, A Bakran.   

Abstract

A significant number of late failures of arteriovenous fistulae for haemodialysis access are related to the progression of intimal hyperplasia. Although the aetiology of this process is still unknown, the geometry of the fistula and the local haemodynamics are thought to be contributory factors. An in-vitro study was carried out to investigate the local haemodynamics in a model of a Cimino-Brescia arteriovenous (AV) fistula with a 30 degrees anastomotic angle and vein-to-artery diameter ratio of 1.6. Flow patterns were obtained by planar illumination of micro-particles suspended in the fluid. Steady and pulsatile flow studies were performed over a range of flow conditions corresponding to those recorded in patients. Quantitative measurements of wall shear stress and turbulence were made using laser Doppler anemometry. The flow structures in pulsatile flow were similar to those seen in steady flow with no significant qualitative changes over the cardiac cycle. This was probably the result of the low pulsatility index of the flow waveform in AV fistulae. Turbulence was the dominant feature in the vein, with relative turbulence intensity > 0.5 within 10 mm of the suture line decreasing to a relatively constant value of about 0.10-0.15 between 40 and 70 mm from the suture line. Peak and mean Reynolds shear stress of 15 and 20 N/m2, respectively, were recorded at the suture line. On the floor of the artery, peak values of temporal mean and oscillating wall shear stress of 9.22 and 29.8 N/m2, respectively. In the vein, both mean and oscillating wall shear stress decreased with distance from the anastomosis.

Entities:  

Mesh:

Year:  1999        PMID: 10460128     DOI: 10.1016/s0021-9290(99)00088-3

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  11 in total

1.  Differential endothelial gap junction expression in venous vessels exposed to different hemodynamics.

Authors:  Chi-Jen Chang; Lung-Sheng Wu; Lung-An Hsu; Gwo-Jyh Chang; Chin-Fen Chen; Hung-I Yeh; Yu-Shien Ko
Journal:  J Histochem Cytochem       Date:  2010-08-30       Impact factor: 2.479

2.  Establishment of a rat autogenous arteriovenous fistula model following 5/6 nephrectomy.

Authors:  Chenfei Zheng; Ying Zhou; Chaoxing Huang; Zhouchang Zhang; Y I Liu; Yulan Xu
Journal:  Exp Ther Med       Date:  2015-04-24       Impact factor: 2.447

3.  Evaluation of the hemodynamics in straight 6-mm and tapered 6- to 8-mm grafts as upper arm hemodialysis vascular access.

Authors:  M Sarmast; H Niroomand-Oscuii; F Ghalichi; E Samiei
Journal:  Med Biol Eng Comput       Date:  2014-08-12       Impact factor: 2.602

Review 4.  Neointimal hyperplasia associated with synthetic hemodialysis grafts.

Authors:  Li Li; Christi M Terry; Yan-Ting E Shiu; Alfred K Cheung
Journal:  Kidney Int       Date:  2008-07-30       Impact factor: 10.612

5.  Hemodynamics in the cephalic arch of a brachiocephalic fistula.

Authors:  M Boghosian; K Cassel; M Hammes; B Funaki; S Kim; X Qian; X Wang; P Dhar; J Hines
Journal:  Med Eng Phys       Date:  2014-03-30       Impact factor: 2.242

Review 6.  Transport physics and biorheology in the setting of hemostasis and thrombosis.

Authors:  L F Brass; S L Diamond
Journal:  J Thromb Haemost       Date:  2016-03-30       Impact factor: 5.824

7.  Computer assisted Doppler waveform analysis and ultrasound derived turbulence intensity ratios can predict early hyperplasia development in newly created vascular access fistula: Pilot study, methodology and analysis.

Authors:  Matthew Bartlett; Vanessa Diaz-Zuccarini; Janice Tsui
Journal:  JRSM Cardiovasc Dis       Date:  2021-03-20

8.  The Effect of Arterial Curvature on Blood Flow in Arterio-Venous Fistulae: Realistic Geometries and Pulsatile Flow.

Authors:  L Grechy; F Iori; R W Corbett; W Gedroyc; N Duncan; C G Caro; P E Vincent
Journal:  Cardiovasc Eng Technol       Date:  2017-07-26       Impact factor: 2.495

9.  High resolution hemodynamic profiling of murine arteriovenous fistula using magnetic resonance imaging and computational fluid dynamics.

Authors:  Daniel Pike; Yan-Ting Shiu; Maheshika Somarathna; Lingling Guo; Tatyana Isayeva; John Totenhagen; Timmy Lee
Journal:  Theor Biol Med Model       Date:  2017-03-20       Impact factor: 2.432

10.  The Anastomotic Angle of Hemodialysis Arteriovenous Fistula Is Associated With Flow Disturbance at the Venous Stenosis Location on Angiography.

Authors:  Chih-Yu Yang; Ming-Chia Li; Chien-Wen Lan; Wang-Jiun Lee; Chen-Ju Lee; Cheng-Hsueh Wu; Jing-Min Tang; Yang-Yao Niu; Yao-Ping Lin; Yan-Ting Shiu; Alfred K Cheung; Yan-Hwa Wu Lee; Oscar Kuang-Sheng Lee; Shu Chien; Der-Cherng Tarng
Journal:  Front Bioeng Biotechnol       Date:  2020-07-23