Literature DB >> 10458931

Thermodiffusion for continuous quantification of hepatic microcirculation--validation and potential in liver transplantation.

E Klar1, T Kraus, J Bleyl, W H Newman, H F Bowman, W J Hofmann, R Kummer, M Bredt, C Herfarth.   

Abstract

Hepatic microcirculation is a main determinant of reperfusion injury and graft quality in liver transplantation. Methods available for the quantification of hepatic microcirculation are indirect, are invasive, or preclude postoperative application. The aim of this study was the validation of thermodiffusion in a new modification allowing long-term use in the clinical setting. In six pigs Doppler flowmeters were positioned around the hepatic artery and portal vein for the measurement of total liver blood flow. Liver perfusion was quantified by thermodiffusion and compared to H(2) clearance as an established technique under baseline conditions, during different degrees of portal venous obstruction and during occlusion of the hepatic artery. Thermodiffusion measurements were recorded for five days postoperatively followed by histological evaluation of the hepatic puncture site. Perfusion data obtained by thermodiffusion were significantly correlated to H(2) clearance (r = 0.94, P < 0. 001) and to liver blood flow (r = 0.9, P < 0.05). The agreement between thermodiffusion and H(2) clearance was excellent (mean difference -2.1 ml/100 g/min; limits of agreement -12.5 and 8.3 ml/100 g/min). Occlusion of the portal vein or hepatic artery was immediately detected by thermodiffusion, indicating a decrease of perfusion by 64 +/- 7% or 27 +/- 5% of baseline, respectively. Perfusion values at baseline and during vascular occlusion were reproducible during the entire observation period. Histological changes of the liver tissue adjacent to the thermodiffusion probes were minute and did not influence long-term measurements. In vivo validation proved that enhanced thermodiffusion is a minimally invasive technique for the continuous, real-time quantification of hepatic microcirculation. Changes in liver perfusion can be safely detected over several days postoperatively. The implication for liver transplantation has led to the clinical application of thermodiffusion. Copyright 1999 Academic Press.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10458931     DOI: 10.1006/mvre.1999.2166

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  3 in total

1.  Xenon-induced flow activation in patients with cerebral insult who undergo xenon-enhanced CT blood flow studies.

Authors:  P Horn; P Vajkoczy; C Thomé; E Muench; L Schilling; P Schmiedek
Journal:  AJNR Am J Neuroradiol       Date:  2001-09       Impact factor: 3.825

2.  Optimizing probe design for an implantable perfusion and oxygenation sensor.

Authors:  Tony J Akl; Ruiqi Long; Michael J McShane; M Nance Ericson; Mark A Wilson; Gerard L Coté
Journal:  Biomed Opt Express       Date:  2011-06-29       Impact factor: 3.732

Review 3.  Aspects on the Physiological and Biochemical Foundations of Neurocritical Care.

Authors:  Carl-Henrik Nordström; Lars-Owe Koskinen; Magnus Olivecrona
Journal:  Front Neurol       Date:  2017-06-19       Impact factor: 4.003

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.