The effect of developer age on the detection of approximal caries using three dental films.

K Syriopoulos1, X L Velders, G C Sanderink, F C van Ginkel, J P van Amerongen, P F van der Stelt.   

Abstract

OBJECTIVES: To compare the diagnostic accuracy for the detection of approximal caries of three dental X-ray films using fresh and aged processing chemicals.
METHODS: Fifty-six extracted unrestored premolars were radiographed under standardized conditions using the new Dentus M2 (Agfa-Gevaert, Mortsel, Belgium), Ektaspeed Plus and Ultra-speed (Kodak Eastman Co, Rochester, USA) dental films. The films were processed manually using Agfa chemicals (Heraeus Kulzer, Dormagen, Germany). The procedure was repeated once a week until the complete exhaustion of the chemicals (6 weeks). Three independent observers assessed 210 radiographs using the following rating scale: 0 = sound, 1 = enamel lesion; 2 = lesion reaching the ADJ; 3 = dentinal lesion. True caries depth was determined by histological examination (14 sound surfaces, 11 enamel lesions, eight lesions reaching the ADJ and 23 dentinal lesions). True caries depth was subtracted from the values given by the observers and an analysis of variance was performed. The null hypothesis was rejected when P < 0.05.
RESULTS: No significant differences were found in the diagnostic accuracy between the three films when using chemicals of up to 3 weeks old (P = 0.056). After the third week, Ultra-speed was significantly better than the other two films (P = 0.012). On average caries depth was underestimated.
CONCLUSION: A similar level of diagnostic accuracy for approximal caries is achieved when using the three films. Dentus M2 and Ektaspeed Plus are at present the fastest available films and they should therefore be recommended for clinical practice. Agfa chemicals should be renewed every 3 weeks. Fifty per cent reduction in average gradient is indicative of renewing processing chemicals.

Mesh:

Substances:

Year:  1999        PMID: 10455383     DOI: 10.1038/sj/dmfr/4600442

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  2 in total

1.  Effects of developer exhaustion on DFL Contrast FV-58 and Kodak Insight dental films.

Authors:  Fabiano Pachêco de Carvalho; M M F da Silveira; M A G Frazão; S T de Santana; M L dos Anjos Pontual
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

2.  The evaluation of effect of developer age in the detection of approximal caries using three speed dental x-ray films: an in-vitro study.

Authors:  Vijaylaxmi B Madalli; Rajeshwari G Annigeri; Shrinivas M Basavaraddi
Journal:  J Clin Diagn Res       Date:  2014-03-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.