Literature DB >> 10453665

Histologic and histomorphometric comparison of immediately placed hydroxyapatite-coated and titanium plasma-sprayed implants: a pilot study in dogs.

C Karabuda1, P Sandalli, S Yalcin, D E Steflik, G R Parr.   

Abstract

The purpose of this pilot study was to make a histologic and histomorphometric comparison of hydroxyapatite-(HA) coated and titanium plasma-sprayed (TPS) root-form implants that were placed in 2 mongrel dogs immediately after extraction of mandibular premolars. After 8 weeks of healing, the implant-containing segments of the mandible were removed en bloc and bone blocks including implants were sectioned. Histologic and histomorphometric analyses were performed by evaluating bone sections. The mean bone contact percentage of HA-coated implants was 61.84 +/- 7.84%, with a range of 52.09% to 75.7%, and the mean bone contact percentage of TPS implants was 51.35 +/- 12.1%, with a range of 30.1% to 70.6%. This pilot study suggests that HA-coated implants placed into fresh extraction sockets can achieve better bone contact than TPS implants, but there was evidence that the surface of the HA layer can be resorbed, so long-term stability of HA coatings in immediate implantation must be investigated.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10453665

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Clinical evaluation of anodized surface implants submitted to a counter torque of 25 ncm after 60 days of osseointegration: study in humans.

Authors:  Rafael Manfro; Marcelo Carlos Bortoluzzi; Vinícius Fabris; Carlos Nelson Elias; Vera Cavalcanti de Araújo
Journal:  J Maxillofac Oral Surg       Date:  2013-09-13

2.  Contribution of the PDL to Osteotomy Repair and Implant Osseointegration.

Authors:  X Pei; L Wang; C Chen; X Yuan; Q Wan; J A Helms
Journal:  J Dent Res       Date:  2017-05-08       Impact factor: 6.116

3.  Alveolar bone regeneration for immediate implant placement using an injectable bone substitute: an experimental study in dogs.

Authors:  Damien Boix; Olivier Gauthier; Jérôme Guicheux; Paul Pilet; Pierre Weiss; Gaël Grimandi; Guy Daculsi
Journal:  J Periodontol       Date:  2004-05       Impact factor: 6.993

4.  Evaluation of Chemical Mechanical Polishing-Based Surface Modification on 3D Dental Implants Compared to Alternative Methods.

Authors:  Riaid Alsaeedi; Z Ozdemir
Journal:  Materials (Basel)       Date:  2018-11-15       Impact factor: 3.623

5.  Bone Morphometric Evaluation around Immediately Placed Implants Covered with Porcine-Derived Pericardium Membrane: An Experimental Study in Dogs.

Authors:  Ryo Jimbo; Charles Marin; Lukasz Witek; Marcelo Suzuki; Nick Tovar; Ioana Chesnoiu-Matei; Irina Florentina Dragan; Paulo G Coelho
Journal:  Int J Biomater       Date:  2012-11-25

6.  Histomorphometric analysis of pure titanium implants with porous surface versus rough surface.

Authors:  Aline Scalone Brentel; Luana Marotta Reis de Vasconcellos; Marize Varella Oliveira; Mário Lima de Alencastro Graça; Luis Gustavo Oliveira de Vasconcellos; Carlos Alberto Alves Cairo; Yasmin Rodarte Carvalho
Journal:  J Appl Oral Sci       Date:  2006-06       Impact factor: 2.698

  6 in total