Literature DB >> 10451917

A comparison of 1-naphthyl phosphate and 4 aminophenyl phosphate as enzyme substrates for use with a screen-printed amperometric immunosensor for progesterone in cows' milk.

R M Pemberton1, J P Hart, P Stoddard, J A Foulkes.   

Abstract

4-Aminophenyl phosphate (4-APP) and 1-naphthyl phosphate (1-NP) were compared as enzyme substrates for an amperometric milk progesterone biosensor utilising progesterone-conjugated alkaline phosphatase in a competitive immunoassay format. Cyclic voltammetry of the corresponding hydrolysis products, 4-aminophenol and 1-naphthol, at the surface of screen-printed carbon base transducers, uncoated or coated with anti-progesterone monoclonal antibody (mAb) showed well-defined anodic responses for both species, with the more sensitive being 4-aminophenol. Scan rate studies produced evidence that surface mAb could impede the diffusion of 4-aminophenol, but not 1-naphthol, toward the electrode surface. This was supported by computer simulation for the electrochemical rate constant (khet) using 4-aminophenol, which gave values at uncoated and mAb-coated electrodes of 6.5 x 10(-4) and 3.0 x 10(-4) cm s-1, respectively. The applied potential for oxidation of 4-aminophenol was 230 mV lower than for 1-naphthol. Nevertheless, by operating below +400 mV versus a saturated calomel reference electrode, it was possible to obtain a chronoamperometric signal for 1-naphthol in the absence of electrochemical interference from milk. Using mAb-coated SPCEs, calibration curves were obtained for progesterone in oestrus whole cow's milk spiked with standard concentrations over the range 0-50 ng/ml, using either 4-APP or 1NP as enzyme substrate. Precision values for triplicate sensors were 5.3-18.3% for 4-APP and 4.1-12.4% for 1-NP. An assay of real whole milk samples from different cows at various stages of the oestrus cycle produced correlations against a commercial EIA of r = 0.840 and 0.946 for 4-APP and 1-NP, respectively, 1-NP possesses the advantages over 4-APP of being inexpensive, easy to obtain and soluble (1-naphthol cf. 4-aminophenol) at high pH. From these observations, it is concluded that 1-NP is the preferred substrate for use with our proposed milk progesterone biosensor.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10451917     DOI: 10.1016/s0956-5663(99)00019-6

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Square-wave voltammetry assays for glycoproteins on nanoporous gold.

Authors:  Binod Pandey; Jay K Bhattarai; Papapida Pornsuriyasak; Kohki Fujikawa; Rosa Catania; Alexei V Demchenko; Keith J Stine
Journal:  J Electroanal Chem (Lausanne)       Date:  2014-03-15       Impact factor: 4.464

2.  A highly sensitive enzyme-amplified immunosensor based on a nanoporous niobium oxide (Nb2O5) electrode.

Authors:  Chang-Soo Lee; Dohyoung Kwon; Jeng Eun Yoo; Byung Gun Lee; Jinsub Choi; Bong Hyun Chung
Journal:  Sensors (Basel)       Date:  2010-05-25       Impact factor: 3.576

3.  Electrochemical Detection and Capillary Electrophoresis: Comparative Studies for Alkaline Phosphatase (ALP) Release from Living Cells.

Authors:  Thanih Balbaied; Anna Hogan; Eric Moore
Journal:  Biosensors (Basel)       Date:  2020-08-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.