Literature DB >> 10451739

Endovascular occlusion of basilar bifurcation aneurysms with electrolytically detachable coils.

G Redekop1, R Willinsky, W Montanera, K TerBrugge, M Tymianski, M C Wallace.   

Abstract

OBJECT: To describe the clinical and angiographic results of endovascular occlusion of basilar bifurcation aneurysms with electrolytically detachable coils, and to identify factors which should be considered in deciding upon surgical or endovascular treatment.
METHODS: We report our experience with 40 patients in whom occlusion of basilar bifurcation aneurysms with electrolytically detachable coils was attempted. All patients underwent superselective angiography and attempted embolization with Guglielmi detachable coils (GDCs). Angiographic and clinical results were prospectively recorded. Twenty-eight aneurysms presented with subarachnoid hemorrhage (SAH), 2 were symptomatic and 10 were incidental.
RESULTS: Coils were not placed in 10 patients (25%) because of unfavorable anatomy. Complete aneurysm occlusion was achieved at the time of the initial procedure in 13 (32.5%), small neck remnants were present in 13 (32.5%), and in 4 (10.0%) there was obvious residual contrast filling of the aneurysm body. Of 23 patients successfully coiled after SAH, 20 were Grade 1 to 3 and 3 were grade 4 or 5 at the time of treatment. Eighteen (78%) made a good recovery. Procedural mortality was 2.5% and permanent morbidity was 7.5%. There were no permanent complications in patients with unruptured aneurysms. Complete aneurysm occlusion was possible in 10 (56%) of 18 aneurysms with small necks and 3 (14%) of 22 with large necks. Follow-up angiography in 25 of 28 surviving patients (mean, 12 months) demonstrated stability of all completely occluded aneurysms. Incompletely coiled aneurysms had variable results on follow-up angiograms: 15.4% improved, 69.2% worsened, and 15.4% were stable. No aneurysm bled after treatment during clinical follow-up averaging 22 months.
CONCLUSIONS: Endovascular treatment of basilar bifurcation aneurysms appears to prevent early aneurysm rebleeding with acceptable rates of morbidity and mortality, but long-term follow-up is required.

Entities:  

Mesh:

Year:  1999        PMID: 10451739     DOI: 10.1017/s0317167100000214

Source DB:  PubMed          Journal:  Can J Neurol Sci        ISSN: 0317-1671            Impact factor:   2.104


  2 in total

1.  Biomedical applications of thermally activated shape memory polymers.

Authors:  Ward Small; Pooja Singhal; Thomas S Wilson; Duncan J Maitland
Journal:  J Mater Chem       Date:  2010-05-14

2.  The value of computed tomography angiography in determining treatment allocation for aneurysmal subarachnoid hemorrhage.

Authors:  Jefferson T Miley; Robert A Taylor; Vallabh Janardhan; Ramachandra Tummala; Giuseppe Lanzino; Adnan I Qureshi
Journal:  Neurocrit Care       Date:  2008       Impact factor: 3.210

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.