Literature DB >> 10450501

The influence of simultaneous intra-aortic balloon pumping and mechanical ventilation on hemodynamic parameters--numerical simulation.

M Darowski1, C De Lazzari, G Ferrari, F Clemente, M Guaragno.   

Abstract

Intra-aortic balloon counterpulsation (IABC) is one of the methods to assist circulation. Its application is supposed to increase coronary blood flow (Qcor) and myocardial oxygen supply. Mechanical ventilation of the lungs causes some side effects that influence mainly hemodynamics, i.e. it decreases cardiac output (CO) and systemic aortic pressure (Pas) but increases systemic venous pressure (Pvs). The aim of this study was to assess the influence of IABC on hemodynamic parameters when mechanical ventilation of the lungs is used as well. We assumed pathological conditions of the heart as reduced left ventricle elastance (Ev = 0.77 mmHg/cm3) and increased left ventricle rest volume (V0 = 10 cm3). Also peripheral systemic arterial resistance (Ras) took three different values. CARDIOSIM, a computer simulator of the human cardiovascular system, was used to assess the changes of hemodynamic parameters [CO, Pas, Pvs, and pulmonary arterial pressure (Pap)] when IABC and mechanical ventilation of the lungs were applied simultaneously. Computer simulation showed that application of IABC increased such variables as CO (by approximately equal to 17%), maximum value of Pas (by approximately equal to 20%), while left atrial pressure (Pla) was diminished (by approximately equal to 30%). On the other hand, Pvs and Pap were not strongly affected by IABC, but they were dramatically dependent on intrathoracic pressure. This means that Pvs, Pap, and Pla should be carefully monitored during IABC and artificial ventilation.

Entities:  

Mesh:

Year:  1999        PMID: 10450501

Source DB:  PubMed          Journal:  Front Med Biol Eng        ISSN: 0921-3775


  3 in total

Review 1.  CARDIOSIM©: The First Italian Software Platform for Simulation of the Cardiovascular System and Mechanical Circulatory and Ventilatory Support.

Authors:  Beatrice De Lazzari; Roberto Badagliacca; Domenico Filomena; Silvia Papa; Carmine Dario Vizza; Massimo Capoccia; Claudio De Lazzari
Journal:  Bioengineering (Basel)       Date:  2022-08-11

2.  Evaluating the hemodynamical response of a cardiovascular system under support of a continuous flow left ventricular assist device via numerical modeling and simulations.

Authors:  Selim Bozkurt; Koray K Safak
Journal:  Comput Math Methods Med       Date:  2013-12-02       Impact factor: 2.238

3.  Simulation as a preoperative planning approach in advanced heart failure patients. A retrospective clinical analysis.

Authors:  Massimo Capoccia; Silvia Marconi; Sanjeet Avtaar Singh; Domenico M Pisanelli; Claudio De Lazzari
Journal:  Biomed Eng Online       Date:  2018-05-02       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.