Literature DB >> 10444187

Immunologic response to recombinant hirudin in HIT type II patients during long-term treatment.

G Huhle1, U Hoffmann, X Song, L C Wang, D L Heene, J Harenberg.   

Abstract

We prospectively investigated 27 patients with heparin-induced thrombocytopenia (HIT) type II who were subsequently treated with r-hirudin. Patients with venous or arterial thromboembolism were treated with activated partial thromboplastin time (aPTT)-controlled intravenous r-hirudin (n = 19; mean 19.3 d) followed by subcutaneous r-hirudin (n = 6; mean 22.5 d) and oral anticoagulation. Patients without thromboembolism were treated with subcutaneous r-hirudin (n = 8; mean 25.9 d). Four patients were readmitted to subcutaneous r-hirudin for a mean duration of 32 d. The incidence of r-hirudin antibodies was 84% for intravenously treated patients and 50% in subcutaneously treated patients. The patients (n = 27) showed a 74% overall incidence of r-hirudin antibodies, mainly of the IgG-subclass, without seroconversion before day 6 and after day 32 of r-hirudin treatment or during r-hirudin treatment. None of the patients showed onset or recurrence of venous or arterial thromboembolism, systemic allergic reactions or IgE-antibody development. During intravenous and subcutaneous administration of r-hirudin the aPTT and the ecarin clotting time was increased in the antibody-positive patients compared to antibody-negative patients. Therefore we assume that r-hirudin antibodies may reduce r-hirudin metabolism.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10444187     DOI: 10.1046/j.1365-2141.1999.01532.x

Source DB:  PubMed          Journal:  Br J Haematol        ISSN: 0007-1048            Impact factor:   6.998


  6 in total

Review 1.  Management of patients with heparin-induced thrombocytopenia: focus on recombinant hirudin.

Authors:  N Lubenow; A Greinacher
Journal:  J Thromb Thrombolysis       Date:  2000-11       Impact factor: 2.300

Review 2.  Laboratory diagnosis of heparin-induced thrombocytopenia and monitoring of alternative anticoagulants.

Authors:  Albrecht Leo; Susanne Winteroll
Journal:  Clin Diagn Lab Immunol       Date:  2003-09

3.  Retention of lepirudin at the tip of a silicone catheter: a better catheter flush solution?

Authors:  McDonald K Horne; Elizabeth Inkellis
Journal:  Support Care Cancer       Date:  2004-02-13       Impact factor: 3.603

4.  Treatment of patients with a history of heparin-induced thrombocytopenia and anti-lepirudin antibodies with argatroban.

Authors:  Job Harenberg; Harenberg Job; Ingrid Jörg; Jörg Ingrid; Tivadar Fenyvesi; Fenyvesi Tivadar; Lukas Piazolo; Piazolo Lukas
Journal:  J Thromb Thrombolysis       Date:  2005-02       Impact factor: 2.300

Review 5.  Antiplatelet medications and evolving antithrombotic medication.

Authors:  Jonathan Ryan; Ferdia Bolster; Ian Crosbie; Eoin Kavanagh
Journal:  Skeletal Radiol       Date:  2013-01-19       Impact factor: 2.199

6.  Lepirudin in the management of patients with heparin-induced thrombocytopenia.

Authors:  Sirak Petros
Journal:  Biologics       Date:  2008-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.