Literature DB >> 10444038

Indoor endotoxin and glucan in association with airway inflammation and systemic symptoms.

G H Wan1, C S Li.   

Abstract

Indoor bioaerosols (i.e., bacteria, fungi, endotoxin, and beta-1,3-glucan) were determined in daycare centers, office buildings, and domestic environments in the Taipei area. In addition, we used a questionnaire survey to determine associations between indoor dampness, bioaerosols, and airway inflammation and systemic symptoms. We demonstrated that the median levels of indoor bacteria and fungi were the highest in daycare centers, followed by those in homes and office buildings. Similar patterns were observed for endotoxin and beta-1,3-glucan. The prevalences of airway inflammation and systemic symptoms were higher for females in office buildings than for employees in daycare centers; all symptoms were more prevalent in females than males. With respect to the relationship between bioaerosol exposure and airway inflammation and systemic symptoms, we found a strong association between beta-1,3-glucan and lethargy/fatigue.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10444038     DOI: 10.1080/00039899909602256

Source DB:  PubMed          Journal:  Arch Environ Health        ISSN: 0003-9896


  15 in total

Review 1.  Onset and outcome of asthma in older adults. A clinician's perspective.

Authors:  Charles E Reed
Journal:  Clin Rev Allergy Immunol       Date:  2002-02       Impact factor: 8.667

2.  Characterization of airborne molds, endotoxins, and glucans in homes in New Orleans after Hurricanes Katrina and Rita.

Authors:  Carol Y Rao; Margaret A Riggs; Ginger L Chew; Michael L Muilenberg; Peter S Thorne; David Van Sickle; Kevin H Dunn; Clive Brown
Journal:  Appl Environ Microbiol       Date:  2007-01-05       Impact factor: 4.792

3.  Characterization of the monthly variation in (1 → 3)-β-D-glucan concentrations in university laboratories.

Authors:  Sung Ho Hwang; Ik Mo Lee; Yun Keun Lee; Jeong Im Park; Kwang Won Rhie; Dong Uk Park; Chung Sik Yoon
Journal:  Environ Monit Assess       Date:  2013-05-01       Impact factor: 2.513

4.  Insomnia is more common among subjects living in damp buildings.

Authors:  C Janson; D Norbäck; E Omenaas; T Gislason; L Nyström; R Jõgi; E Lindberg; M Gunnbjörnsdottir; E Norrman; T Wentzel-Larsen; C Svanes; E J Jensen; K Torén
Journal:  Occup Environ Med       Date:  2005-02       Impact factor: 4.402

5.  Enzyme-linked immunosorbent assay specific for (1-->6) branched, (1-->3)-beta-D-glucan detection in environmental samples.

Authors:  D K Milton; K U Alwis; L Fisette; M Muilenberg
Journal:  Appl Environ Microbiol       Date:  2001-12       Impact factor: 4.792

6.  Evaluation of lot-to-lot repeatability and effect of assay media choice in the recombinant Factor C assay.

Authors:  Jennifer Helen McKenzie; K Udeni Alwis; Joanne E Sordillo; Kesava Srinivas Kalluri; Donald Kirby Milton
Journal:  J Environ Monit       Date:  2011-05-09

7.  Innate immune responses of airway epithelium to house dust mite are mediated through beta-glucan-dependent pathways.

Authors:  Amy T Nathan; Elizabeth A Peterson; Jamila Chakir; Marsha Wills-Karp
Journal:  J Allergy Clin Immunol       Date:  2009-03       Impact factor: 10.793

8.  Characterization of the microbial community in indoor environments: a chemical-analytical approach.

Authors:  Aleksandra Sebastian; Lennart Larsson
Journal:  Appl Environ Microbiol       Date:  2003-06       Impact factor: 4.792

9.  Fungal pollution of indoor environments and its management.

Authors:  A A Haleem Khan; S Mohan Karuppayil
Journal:  Saudi J Biol Sci       Date:  2012-06-15       Impact factor: 4.219

10.  House dust (1-3)-beta-D-glucan and wheezing in infants.

Authors:  Y Y Iossifova; T Reponen; D I Bernstein; L Levin; H Kalra; P Campo; M Villareal; J Lockey; G K K Hershey; G LeMasters
Journal:  Allergy       Date:  2007-05       Impact factor: 13.146

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.