Determination of calcaneal ultrasound properties ex situ: reproducibility, effects of storage, formalin fixation, maceration, and changes in anatomic measurement site.

G Pöpperl1, E Lochmüller, H Becker, G Mall, M Steinlechner, F Eckstein.   

Abstract

The objective of this study was to determine the reproducibility of ultrasonic bone properties with a system for measuring calcanei ex situ; the influence of changes of the measurement site; and the effects of fixation, storage, and maceration. We examined 14 fixed calcanei and 12 fresh bones. Ultrasonic measurements were performed ex situ after degassing, using an Achilles+ system and a special positioning device. The instrument precision was 0.16% for speed of sound (SOS), 1.4% for broadband ultrasonic attenuation (BUA), and 1. 8% for the stiffness index (SI). The short-term precision was 0.54%, 1.9%, and 2.8%, respectively. A defined shift of the measurement site (5 mm distal of the middle) led to unpredictable changes in ultrasound (US) properties (r = 0.65 for SOS, 0.82 for BUA, and 0.75 for SI). Embalment with 4% formalin/96% alcohol caused a systematic decrease in SOS, an increase in BUA, and a decrease in SI (mean = -12.7 units; P < 0.001), the effect increasing with time. However, values at 6 months of fixation and later were highly correlated with those in fresh specimens (r = 0.95 for the SI). Two weeks storage in degassed and normal solution had only modest effects on ultrasound properties. Maceration did not lead to a systematic increase or decrease of ultrasound variables, but introduced unpredictable changes (r = 0.64-0.94). We conclude that in comparative biomechanical studies it is feasible to measure calcaneal specimens embalmed in formalin/alcohol ex situ, if the primary interest is not in the absolute values but in the correlation with mechanical failure loads at other skeletal sites.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10441649     DOI: 10.1007/s002239900681

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  2 in total

1.  Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)?

Authors:  M Hudelmaier; V Kuhn; E M Lochmüller; H Well; M Priemel; T M Link; F Eckstein
Journal:  Osteoporos Int       Date:  2004-01-22       Impact factor: 4.507

2.  Elastic modulus of the femoral trochanteric region measured by scanning acoustic microscopy in elderly women.

Authors:  Hiroyuki Matsuki; Junichi Shibano; Michiaki Kobayashi; Yukio Nakatsuchi; Tetsuji Moriizumi; Hiroyuki Kato
Journal:  J Med Ultrason (2001)       Date:  2015-01-25       Impact factor: 1.314

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.