Literature DB >> 10440960

Intimate combination of low- and high-resolution image data: I. Real-space PET and (1)H(2)O MRI, PETAMRI.

M K Sammi1, C A Felder, J S Fowler, J H Lee, A V Levy, X Li, J Logan, I Pályka, W D Rooney, N D Volkow, G J Wang, C S Springer.   

Abstract

Two different types of (co-registered) images of the same slice of tissue will generally have different spatial resolutions. The judicious pixel-by-pixel combination of their data can be accomplished to yield a single image exhibiting properties of both. Here, axial (18)FDG PET and (1)H(2)O MR images of the human brain are used as the low- and high-resolution members of the pair. A color scale is necessary in order to provide for separate intensity parameters from the two image types. However, not all color scales can accommodate this separability. The HSV color model allows one to choose a color scale in which the intensity of the low-resolution image type is coded as hue, while that of the high-resolution type is coded as value, a reasonably independent parameter. Furthermore, the high-resolution image must have high contrast and be quantitative in the same sense as the low-resolution image almost always is. Here, relaxographic MR images (naturally segmented quantitative (1)H(2)O spin-density components) are used. Their essentially complete contrast serves to effect an apparent editing function when encoded as the value of the color scale. Thus, the combination of (18)FDG PET images with gray-matter (GM) relaxographic (1)H(2)O images produces visually "GM-edited" (18)FDG PETAMR (positron emission tomography and magnetic resonance) images. These exhibit the high sensitivity to tracer amounts characteristic of PET along with the high spatial resolution of (1)H(2)O MRI. At the same time, however, they retain the complete quantitative measures of each of their basis images. Magn Reson Med 42:345-360, 1999. Published 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10440960     DOI: 10.1002/(sici)1522-2594(199908)42:2<345::aid-mrm17>3.0.co;2-e

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  2 in total

Review 1.  Fusion viewer: a new tool for fusion and visualization of multimodal medical data sets.

Authors:  Karl G Baum; María Helguera; Andrzej Krol
Journal:  J Digit Imaging       Date:  2007-10-25       Impact factor: 4.056

2.  Evaluation of novel genetic algorithm generated schemes for positron emission tomography (PET)/magnetic resonance imaging (MRI) image fusion.

Authors:  K G Baum; E Schmidt; K Rafferty; A Krol; María Helguera
Journal:  J Digit Imaging       Date:  2011-12       Impact factor: 4.056

  2 in total