MR fluoroscopy using projection reconstruction multi-gradient-echo (prMGE) MRI.

V Rasche1, D Holz, R Proksa.   

Abstract

A projection reconstruction multi-gradient-echo (prMGE) technique is presented. The introduced technique is an extension of a standard projection reconstruction steady-state gradient-echo technique allowing for the acquisition of several gradient echoes after each excitation of the spin system. Each echo train is used for acquiring data of a certain angular segment of k-space. By use of echo trains consisting of up to four echoes, the overall acquisition time for a 128(2) image can be reduced to 150 ms without sacrificing image quality. Results are presented for cardiac fluoroscopy, for the visualization of swallowing, and for the visualization of joint motion. For all investigated applications promising results have been obtained. Especially in parts of the body where motion on an even shorter time scale than the acquisition process or significant in-plane or through-plane flow are within the field of view, the introduced technique appears to be a promising technique for MR fluoroscopy. Magn Reson Med 42:324-334, 1999. Copyright 1999 Wiley-Liss, Inc.

Mesh:

Year:  1999        PMID: 10440958     DOI: 10.1002/(sici)1522-2594(199908)42:2<324::aid-mrm15>3.0.co;2-r

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Centering the projection reconstruction trajectory: reducing gradient delay errors.

Authors:  Dana C Peters; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

2.  Large field-of-view real-time MRI with a 32-channel system.

Authors:  Christopher J Hardy; Robert D Darrow; Manojkumar Saranathan; Randy O Giaquinto; Yudong Zhu; Charles L Dumoulin; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

3.  CAPTURE: Consistently Acquired Projections for Tuned and Robust Estimation: A Self-Navigated Respiratory Motion Correction Approach.

Authors:  Cihat Eldeniz; Tyler Fraum; Amber Salter; Yasheng Chen; H Michael Gach; Parag J Parikh; Kathryn J Fowler; Hongyu An
Journal:  Invest Radiol       Date:  2018-05       Impact factor: 6.016

4.  Selective 3D ultrashort TE imaging: comparison of "dual-echo" acquisition and magnetization preparation for improving short-T 2 contrast.

Authors:  Jürgen Rahmer; Ulrike Blume; Peter Börnert
Journal:  MAGMA       Date:  2007-03-13       Impact factor: 2.310

5.  3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Youngkyoo Jung; Walter F Block; Sean B Fain
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

6.  Self-calibrated multiple-echo acquisition with radial trajectories using the conjugate gradient method (SMART-CG).

Authors:  Youngkyoo Jung; Alexey A Samsonov; Mark Bydder; Walter F Block
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

7.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

8.  Towards clinical assessment of velopharyngeal closure using MRI: evaluation of real-time MRI sequences at 1.5 and 3 T.

Authors:  A D Scott; R Boubertakh; M J Birch; M E Miquel
Journal:  Br J Radiol       Date:  2012-07-17       Impact factor: 3.039

Review 9.  A half-century of innovation in technology-preparing MRI for the 21st century.

Authors:  Peter Börnert; David G Norris
Journal:  Br J Radiol       Date:  2020-06-15       Impact factor: 3.039

10.  Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions.

Authors:  Wei Lin; Junyu Guo; Mark A Rosen; Hee Kwon Song
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.