Application of a birdcage coil at 3 Tesla to imaging of the human knee using MRI.

D M Peterson1, C E Carruthers, B L Wolverton, K Meister, M Werner, G R Duensing, J R Fitzsimmons.   

Abstract

A transceive RF birdcage coil designed for very high field with a novel matching scheme was implemented with the specific geometry chosen for the human knee. This coil design incorporates a hinge for greater patient accessibility. Volunteer human subjects were studied using spin-echo and 3D gradient echo sequences for image acquisition. The higher signal-to-noise and improved tissue contrast obtained from this high-field system, coupled with the optimized coil design, improves visualization of the structural detail in articular cartilage, which is not seen well at conventional field strengths. This has important clinical implications, as newer medical and surgical treatments become available for the treatment of early cartilage degeneration. Magn Reson Med 42:215-221, 1999. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10440944     DOI: 10.1002/(sici)1522-2594(199908)42:2<215::aid-mrm1>3.0.co;2-8

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences.

Authors:  N Morakkabati-Spitz; J Gieseke; C Kuhl; G Lutterbey; M von Falkenhausen; F Traeber; O Zivanovic; H H Schild
Journal:  Eur Radiol       Date:  2004-12-31       Impact factor: 5.315

2.  Is the body-coil at 3 Tesla feasible for the MRI evaluation of the painful knee? A comparative study.

Authors:  G Lutterbey; K Behrends; M V Falkenhausen; M P Wattjes; N Morakkabati; J Gieseke; H Schild
Journal:  Eur Radiol       Date:  2006-04-08       Impact factor: 5.315

3.  4T split TEM volume head and knee coils for improved sensitivity and patient accessibility.

Authors:  Nikolai I Avdievich; Ken Bradshaw; Jing-Huei Lee; Andrey M Kuznetsov; Hoby P Hetherington
Journal:  J Magn Reson       Date:  2007-05-16       Impact factor: 2.229

4.  MRI of the pelvis at 3 T: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan time.

Authors:  Nuschin Morakkabati-Spitz; Jürgen Gieseke; Christiane Kuhl; Götz Lutterbey; Marcus von Falkenhausen; Frank Träber; Tjoung-Won Park-Simon; Oliver Zivanovic; Hans H Schild
Journal:  Eur Radiol       Date:  2005-10-14       Impact factor: 5.315

5.  Magnetic resonance arthrography of the hip: technique and spectrum of findings in younger patients.

Authors:  Sébastien Aubry; Danny Bélanger; Caroline Giguère; Martin Lavigne
Journal:  Insights Imaging       Date:  2010-06-08
  5 in total