Literature DB >> 10440854

Four color compensation.

C C Stewart1, S J Stewart.   

Abstract

Four-color immunophenotyping can now be routinely performed using either a single laser or dual laser flow cytometer. When a single laser instrument is used, the fluorochromes evaluated are usually FITC, PE, PE-TR and PE-CY5 (or PerCP). For two-laser excitation APC is generally used in place of PE-TR. Since each tandem dye construct contains PE, three of the four detectors are affected and compensation can be problematic. In this report we show that each tandem conjugated antibody, whether different batches from the same supplier or conjugates from different suppliers all require unique compensation. This inconsistency results in erroneous data, negates the use of single labeled particles as a method for providing adequate compensation and requires dual and triple labeled cells of known pattern to verify compensation. It is also shown that improper compensation can reduce or eliminate completely the detection of fluorescence emission from PECY5 conjugated antibodies. These problems are caused by a variation in energy transfer between PE and either TR or CY5 because the chemistry involved in preparation and conjugation to antibodies is not sufficiently controlled to produce reagents with uniform compensation requirements. The variation in tandem dye compensation can be addressed by either using the same tandem conjugated antibody, by using the same second step tandem reagent to an appropriate first step antibody or by using software compensation. The latter provides an easy solution because a unique compensation matrix can be produced for each antibody tandem conjugate. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10440854     DOI: 10.1002/(sici)1097-0320(19990815)38:4<161::aid-cyto3>3.3.co;2-1

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  5 in total

1.  Cytometric sorting based on the fluorescence lifetime of spectrally overlapping signals.

Authors:  Ruofan Cao; Varayini Pankayatselvan; Jessica P Houston
Journal:  Opt Express       Date:  2013-06-17       Impact factor: 3.894

2.  Nucleic acid vaccination with Schistosoma mansoni antioxidant enzyme cytosolic superoxide dismutase and the structural protein filamin confers protection against the adult worm stage.

Authors:  Rosemary M Cook; Claudia Carvalho-Queiroz; Gregory Wilding; Philip T LoVerde
Journal:  Infect Immun       Date:  2004-10       Impact factor: 3.441

3.  Data-driven compensation for flow cytometry of solid tissues.

Authors:  Nickolaas Maria van Rodijnen; Math Pieters; Sjack Hoop; Marius Nap
Journal:  Adv Bioinformatics       Date:  2011-09-06

4.  Polystyrene microspheres enable 10-color compensation for immunophenotyping of primary human leukocytes.

Authors:  Tiara Byrd; Karen D Carr; John C Norman; Leslie Huye; Meenakshi Hegde; Nabil Ahmed
Journal:  Cytometry A       Date:  2015-07-22       Impact factor: 4.355

Review 5.  EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols.

Authors:  T Kalina; J Flores-Montero; V H J van der Velden; M Martin-Ayuso; S Böttcher; M Ritgen; J Almeida; L Lhermitte; V Asnafi; A Mendonça; R de Tute; M Cullen; L Sedek; M B Vidriales; J J Pérez; J G te Marvelde; E Mejstrikova; O Hrusak; T Szczepański; J J M van Dongen; A Orfao
Journal:  Leukemia       Date:  2012-09       Impact factor: 11.528

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.