Literature DB >> 10440649

Aortic valve replacement with stentless porcine bioprostheses.

T E David1.   

Abstract

The implantation of stentless porcine valves (SPVs) is technically more demanding than implantation of stented bioprosthetic valves. Implantation of the Toronto SPV bioprosthesis requires an,understanding of the relationships between the leaflets and the aortic annulus and sinotubular junction. In addition to proper alignment of the three commissures within the aortic root, the diameter of sinotubular junction should not exceed the external diameter of the porcine aortic valve after completion of the operation. The Medtronic Freestyle porcine aortic root bioprosthesis can be used for subcoronary implantation as well as for aortic root replacement. Degenerative calcification of a tricuspid aortic valve is the most common cause of aortic valve disease in older patients. Implantation of stentless valves in the subcoronary position is usually feasible because the geometry of the aortic root is well maintained in these patients. The bicuspid aortic valve is the second most common cause of aortic valve disease in older patients and the most common in younger patients. These patients frequently have dilated aortic root, and the Medtronic Freestyle bioprosthesis is ideal for implantation using the root inclusion technique. Stentless porcine bioprostheses are minimally obstructive and associated with low mean systolic gradients. In addition, they have better hemodynamic performance during exercise than stented bioprostheses. For these reasons, patient-prosthesis mismatch has not been described with stentless valves. Left ventricular function after aortic valve replacement appears to be better with stentless than with stented bioprostheses. Comparative, nonrandomized studies of aortic valve replacement with stented and stentless valves suggest that the risk of cardiac death is reduced with stentless valves and the rates of valve-related complications also appear to be lower. What remains unknown is whether stentless valves are more durable than stented ones.

Entities:  

Mesh:

Year:  1998        PMID: 10440649     DOI: 10.1111/j.1540-8191.1998.tb01096.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  4 in total

1.  Aluminum chloride pretreatment of elastin inhibits elastolysis by matrix metalloproteinases and leads to inhibition of elastin-oriented calcification.

Authors:  M Bailey; H Xiao; M Ogle; N Vyavahare
Journal:  Am J Pathol       Date:  2001-12       Impact factor: 4.307

Review 2.  Newer concepts in the surgical treatment of valvular heart disease.

Authors:  Edward Y Sako
Journal:  Curr Cardiol Rep       Date:  2004-03       Impact factor: 2.931

3.  Transesophageal Echocardiography in Healthy Young Adult Male Baboons (Papio hamadryas anubis): Normal Cardiac Anatomy and Function in Subhuman Primates Compared to Humans.

Authors:  Arthur A Bert; William B Drake; Rachael W Quinn; Kathleen M Brasky; James E O'Brien; Gary K Lofland; Richard A Hopkins
Journal:  Prog Pediatr Cardiol       Date:  2013-08-01

4.  Freestyle aortic root prosthesis in combination with aortic replacement and open anastomosis: a retrospective analysis.

Authors:  Alicja Zientara; Kim Rosselet-Droux; Hans Bruijnen; Dragan Odavic; Michele Genoni; Omer Dzemali
Journal:  J Cardiothorac Surg       Date:  2021-06-26       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.