Literature DB >> 10439752

Predicting the difficult neuraxial block: a prospective study.

J Sprung1, D L Bourke, J Grass, J Hammel, E Mascha, P Thomas, I Tubin.   

Abstract

UNLABELLED: Anticipated technical difficulty is one factor that can influence the anesthesiologist's decision to perform neuraxial (spinal or epidural) blockade. Problems during the procedure may be associated with patient dissatisfaction, neurologic sequelae, or hematoma. We designed this study of 595 neuraxial blocks to determine whether any patient characteristics would be useful in predicting a difficult neuraxial block. Before the procedure, the following data were noted: demographic data, body habitus (normal, thin, muscular, obese), spinal landmarks (good = easily palpable spinous processes, poor = difficult to palpate spinous processes, none = unable to positively identify spinous processes), and spinal anatomy (assessed by inspection and examination as normal or deformed). We noted the technique, approach, needle type, needle gauge, etc. We also recorded whether the procedure was completed at the first (first-level success) or second spinal level and the total number of new skin punctures (attempts) necessary to complete the procedure. Of all the factors considered, the quality of landmarks best correlated with technical difficulty as measured by both first-level success and number of attempts. Abnormal spinal anatomy correlated with difficulty as measured by number of attempts. Body habitus also correlated with difficulty, but only as measured by number of attempts. There was no association between either measure of difficulty and any of the following: age, sex, spinal versus epidural, approach, needle type, needle gauge, or training level of the provider. Thoracic epidurals were less difficult than lumbar epidurals by both measures of difficulty. We conclude that body habitus does not seem to be the best predictor of technical difficulty. An examination of the patient's back for the quality of landmarks and obvious anatomical deformity better predicts the ease or difficulty of neuraxial block. Other factors seem to have little or no influence on the difficulty of neuraxial block procedures. IMPLICATIONS: We studied a number of factors, including equipment, technique, and patient characteristics, that may indicate the ease or difficulty of performing neuraxial (spinal and epidural) blocks. Of these factors, only patient characteristics had significant predictive value. We found that an examination of the patient's back for the quality of landmarks and obvious anatomical deformity better predicts the ease or difficulty of neuraxial block than does body habitus.

Entities:  

Mesh:

Year:  1999        PMID: 10439752     DOI: 10.1097/00000539-199908000-00025

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  24 in total

1.  Modified 45-degree head-up tilt increases success rate of lumbar puncture in patients undergoing spinal anesthesia.

Authors:  Sevtap Hekimoglu Sahin; Alkin Colak; Cavidan Arar; Ilker Yıldırım; Necdet Sut; Alparslan Turan
Journal:  J Anesth       Date:  2014-01-04       Impact factor: 2.078

2.  Increasing body mass index predicts increasing difficulty, failure rate, and time to discovery of failure of epidural anesthesia in laboring patients.

Authors:  Ayse O Kula; Matthias L Riess; Elizabeth H Ellinas
Journal:  J Clin Anesth       Date:  2017-01-10       Impact factor: 9.452

3.  Development of a Head-Mounted Holographic Needle Guidance System for Enhanced Ultrasound-Guided Neuraxial Anesthesia: System Development and Observational Evaluation.

Authors:  Jaya Tanwani; Fahad Alam; Clyde Matava; Stephen Choi; Paul McHardy; Oskar Singer; Geraldine Cheong; Julian Wiegelmann
Journal:  JMIR Form Res       Date:  2022-06-23

4.  Practicability and patients' subjective experiences of low-dose spinal anaesthesia using hyperbaric bupivacaine for transanal surgery.

Authors:  Marc D Schmittner; Andrea Janke; Christel Weiss; Grietje C Beck; Dieter G Bussen
Journal:  Int J Colorectal Dis       Date:  2009-03-13       Impact factor: 2.571

5.  Preprocedural Ultrasonography Versus Landmark-Guided Spinal Anesthesia in Geriatric Patients with Difficult Anatomy: A Prospective Randomized Trial.

Authors:  Yasin Uyel; Alper Kilicaslan
Journal:  Eurasian J Med       Date:  2020-11-23

6.  Predicting the difficulty in performing a neuraxial blockade.

Authors:  Jong Hae Kim; Seok Young Song; Baek Jin Kim
Journal:  Korean J Anesthesiol       Date:  2011-11-23

7.  "Difficult back", turns into "less difficult back" by ultrasonography.

Authors:  Yoon-Hee Kim
Journal:  Korean J Anesthesiol       Date:  2011-11-23

8.  Correlation between spinous process dimensions and ease of spinal anaesthesia.

Authors:  Hariharan Shankar; Kanishka Rajput; Karthik Murugiah
Journal:  Indian J Anaesth       Date:  2012-05

9.  Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach.

Authors:  P H Conroy; C Luyet; C J McCartney; P G McHardy
Journal:  Anesthesiol Res Pract       Date:  2013-01-10

10.  Failure rate of labor epidural: An observational study among different levels of trainee anesthesiologists in a university hospital of a developing country.

Authors:  Samina Ismail; Amir Raza; Kahif Munshi; Rabia Tabassum
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-07-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.