On-line monitoring of radiotherapy beams: experimental results with proton beams.

D W Litzenberg1, D A Roberts, M Y Lee, K Pham, A M Vander Molen, R Ronningen, F D Becchetti.   

Abstract

Proton radiotherapy is a powerful tool in the local control of cancer. The advantages of proton radiotherapy over gamma-ray therapy arise from the phenomenon known as the Bragg peak. This phenomenon enables large doses to be delivered to well-defined volumes while sparing surrounding healthy tissue. To fully realize the potential of this technique the location of the high-dose volume must be controlled very accurately. An imaging system was designed and tested to monitor the positron-emitting activity created by the beam as a means of verifying the beam's range, monitoring dose, and determining tissue composition. The prototype imaging system consists of 12 pairs of cylindrical BGO detectors shielded in lead. Each crystal was 1.9 cm in diameter, 5.0 cm long, and separated by 0.5 cm from other detectors in the row. These are arranged in two rows, 60 cm apart, with the proton beam and tissue phantoms half-way between and parallel to the detector rows. Experiments were conducted with 150 MeV continuous and macro-pulsed proton beams which had beam currents ranging from 0.14 nA to 1.75 nA. The production and decay of short-lived isotopes, 15O and 14O, was studied using 1 min irradiations with a continuous beam. These isotopes provide a significant signal on short time scales, making on-line imaging possible. Macro-pulsed beams, having a period of 10 s, were used to study on-line imaging and the production and decay of long-lived isotopes, 13N, 11C, and 18F. Decay data were acquired and on-line images were obtained between beam pulses and indicate that range verification is possible, for a 150 MeV beam, after one beam pulse, to within the 1.2 cm resolution limit of the imaging system. The dose delivered to the patient may also be monitored by observing the increase in the number of coincidence events detected between successive beam pulses. Over 80% of the initial positron-emitting activity is from 15O while the remainder is primarily 11C, 13N, 14O with traces of 18F, and 10C. Radioisotopic imaging may also be performed along the beam path by fitting decay data collected after the treatment is complete. Using this technique, it is shown that variations in elemental composition in inhomogenous treatment volumes may be identified and used to locate anatomic landmarks. Radioisotopic imaging also reveals that 14O is created well beyond the Bragg peak, apparently by secondary neutrons.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10436901     DOI: 10.1118/1.598491

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Experimental verification of the utility of positron emitter nuclei generated by photonuclear reactions for X-ray beam monitoring in a phantom.

Authors:  Teiji Nishio; Taku Inaniwa; Kazumasa Inoue; Aya Miyatake; Keiichi Nakagawa; Kiyoshi Yoda; Takashi Ogino
Journal:  Radiat Med       Date:  2007-12-25

2.  Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code.

Authors:  K Parodi; A Ferrari; F Sommerer; H Paganetti
Journal:  Phys Med Biol       Date:  2007-05-17       Impact factor: 3.609

Review 3.  Update on novel trends in PET/CT technology and its clinical applications.

Authors:  Stephan Walrand; Michel Hesse; François Jamar
Journal:  Br J Radiol       Date:  2016-11-25       Impact factor: 3.039

Review 4.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

Review 5.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

6.  Feasibility study of using fall-off gradients of early and late PET scans for proton range verification.

Authors:  Jongmin Cho; Kira Grogg; Chul Hee Min; Xuping Zhu; Harald Paganetti; Hyun Cheol Lee; Georges El Fakhri
Journal:  Med Phys       Date:  2017-03-30       Impact factor: 4.071

7.  Proton therapy dosimetry using positron emission tomography.

Authors:  Matthew T Studenski; Ying Xiao
Journal:  World J Radiol       Date:  2010-04-28

8.  Design study of an in situ PET scanner for use in proton beam therapy.

Authors:  S Surti; W Zou; M E Daube-Witherspoon; J McDonough; J S Karp
Journal:  Phys Med Biol       Date:  2011-04-05       Impact factor: 3.609

9.  Feasibility of proton-activated implantable markers for proton range verification using PET.

Authors:  Jongmin Cho; Geoffrey Ibbott; Michael Gillin; Carlos Gonzalez-Lepera; Uwe Titt; Harald Paganetti; Matthew Kerr; Osama Mawlawi
Journal:  Phys Med Biol       Date:  2013-10-08       Impact factor: 3.609

10.  Determination of elemental tissue composition following proton treatment using positron emission tomography.

Authors:  Jongmin Cho; Geoffrey Ibbott; Michael Gillin; Carlos Gonzalez-Lepera; Chul Hee Min; Xuping Zhu; Georges El Fakhri; Harald Paganetti; Osama Mawlawi
Journal:  Phys Med Biol       Date:  2013-05-16       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.