Literature DB >> 10436760

Harmonic grey scale imaging of the human brain.

G Seidel1, C Greis, J Sonne, M Kaps.   

Abstract

Harmonic imaging increases the signal-to-noise ratio in grey-scale imaging. With the use of ultrasound contrast agents (UCA), imaging of brain perfusion seems possible. The authors used an ultrasound system in connection with a 1.8/3.6-MHz harmonic sector transducer and an acoustic densitometry unit for quantification of ultrasound intensity in the thalamus (THAL), the temporoparietal white matter (TPWM), and the lateral fissure (LF). Ten milliliters of BY963, a spherosome-air-based UCA, was injected intravenously in 12 healthy volunteers. Time-intensity curves were calculated. Mean increase of intensity (standard deviation [SD]), mean area under the time-intensity curve (AUC) from baseline (SD), and mean transit time (MTT) (SD) in the region of LF, THAL, and TPWM were 2.2 +/- 1.7, 1.1 +/- 0.6, 0.9 +/- 0.9 dB and 16.7 +/- 22.7, 4.7 +/- 4.7, 3.7 +/- 6.3 as well as 11.1 +/- 3.5, 9.7 +/- 3.1, and 11.9 +/- 8.0, respectively. There was a statistically significant difference for mean AUC (p = 0.02) but none comparing mean intensity increase (p = 0.07) and MTT (p = 0.9). The authors' study indicates that different regions of the human brain show different time-intensity curves. These results suggest that it is possible to measure parameters closely related to perfusion in various regions of the adult human brain.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10436760     DOI: 10.1111/jon199993171

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  5 in total

1.  Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging.

Authors:  J Federlein; T Postert; S Meves; S Weber; H Przuntek; T Büttner
Journal:  J Neurol Neurosurg Psychiatry       Date:  2000-11       Impact factor: 10.154

2.  Microbubbles traversing the blood-brain barrier for imaging and therapy.

Authors:  Stephen Meairs; Angelika Alonso; Marc Fatar; Rolf Kern; Michael Hennerici
Journal:  Med Biol Eng Comput       Date:  2009-03-13       Impact factor: 2.602

3.  Ultrasonic evaluation with second harmonic imaging and SonoVue in the assessment of cerebral perfusion in diabetic patients: a case-control study.

Authors:  Giuseppe Caruso; Giuseppe Salvaggio; Pietro Ragusa; Giuseppe Brancatelli; Roberto Lagalla
Journal:  Eur Radiol       Date:  2004-09-11       Impact factor: 5.315

4.  Ultrasound evaluation of normal and abnormal fetuses: comparison of conventional, tissue harmonic, and pulse-inversion harmonic imaging techniques.

Authors:  Jeong-Ah Ryu; Bohyun Kim; Sooah Kim; Soon Ha Yang; Moon Hae Choi; Hyeong Sik Ahn
Journal:  Korean J Radiol       Date:  2003 Jul-Sep       Impact factor: 3.500

5.  Is ultrasound perfusion imaging capable of detecting mismatch? A proof-of-concept study in acute stroke patients.

Authors:  Raluca Reitmeir; Jens Eyding; Markus F Oertel; Roland Wiest; Jan Gralla; Urs Fischer; Pierre-Yves Giquel; Stefan Weber; Andreas Raabe; Heinrich P Mattle; Werner J Z'Graggen; Jürgen Beck
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.