Literature DB >> 10436202

Scintigraphic evaluation of myocardial ischaemia using a new fatty acid analogue: iodine-123-labelled 15-(p-iodophenyl)-9-(R, S)-methylpentadecanoic acid (9MPA).

J Hashimoto1, A Kubo, R Iwasaki, H Fujii, E Kunieda, S Iwanaga, H Mitamura, S Ogawa.   

Abstract

Iodine-123-labelled 15-(p-iodophenyl)-9-(R,S)-methylpentadecanoic acid (9MPA) is a branched fatty acid analogue for myocardial imaging, which has been recently designed for medium washout rates from the myocardium. The purpose of this study was to assess the clinical feasibility of use of 9MPA for the evaluation of myocardial ischaemia. Twenty-one patients were injected with 9MPA at rest, and sequential single-photon emission tomography (SPET) acquisitions were performed 5, 45 and 240 min after administration to calculate washout rates from the myocardium. The findings of 9MPA images were analysed in comparison with those of perfusion images with thallium-201 or sestamibi, coronary angiography and left venticulography. In general, reduction of 9MPA uptake was more remarkable than that of perfusion tracers. The findings of 9MPA early images correlated better with those of exercise perfusion images than with the rest images. Measured washout rates of 9MPA from ischaemic myocardium were significantly slower than those from normal myocardium. The majority of areas with abnormal 9MPA distribution manifested wall motion abnormality, while all areas with normal tracer distribution presented normal wall motion. The detectability of myocardial ischaemia was improved by adding mid and delayed images in six cases. However, both washout and fill-in patterns were encountered in ischaemic lesions, rendering the interpretation of images difficult. In conclusion, the results of this study indicated that 9MPA has acceptable myocardial uptake, that its use is feasible for the detection of ischaemia and that the abnormal distribution of the tracer correlates well with wall motion abnormality reflecting metabolic disorders.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10436202     DOI: 10.1007/s002590050463

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  2 in total

Review 1.  Metabolic imaging using SPECT.

Authors:  Junichi Taki; Ichiro Matsunari
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06       Impact factor: 9.236

2.  Detection of viable myocardium with p-iodophenyl-9-(R,S)-methylpentadecanoic acid in ischemic rat myocardium.

Authors:  Shinji Hasegawa; Hideo Kusuoka; Kaoru Maruyama; Hiroyuki Kurosawa; Syusaku Tazawa; Satoshi Ishida; Minoru Inoue; Masatsugu Hori; Tsunehiko Nishimura
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.