Comparison of a multi-leaf collimator with conformal blocks for the delivery of stereotactically guided conformal radiotherapy.

E J Adams1, V P Cosgrove, S F Shepherd, A P Warrington, J L Bedford, C D Mubata, A M Bidmead, M Brada.   

Abstract

Stereotactically-guided conformal radiotherapy is a practical technique for irradiating irregular lesions in the brain. The shaping of the conformal fields may be achieved using lead alloy blocks, a conventional multi-leaf collimator (MLC) or a mini/micro-MLC. Although the former gives more precise shaping, it is labour intensive. The latter methods are more practical as both mould room and treatment room times are reduced, but the shaping is limited by the finite leaf-width. This study compares treatment plans, in terms of normal tissue doses and tumour coverage, for fields shaped using conformal blocks and a conventional MLC in two series of geometrical shapes and nine patient tumours. For the range of tumour sizes considered (volumes 14-264 cm3, minimum dimension 30 mm, maximum 102 mm), the MLC treats, on average, 14% (range 3-34%) and 17% (range 0-36%) more normal brain tissue than conformal blocks to >50% and >80% of the prescription dose, respectively. The large variability is due to strong dependence on tumour shape and the presence of partial leaf-widths in the MLC fit. It is therefore important to consider both of these effects when deciding whether the MLC is appropriate for a particular target volume.

Entities:  

Mesh:

Year:  1999        PMID: 10435814     DOI: 10.1016/s0167-8140(99)00062-6

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance - a planning study.

Authors:  Klaus Bratengeier; Barbara Herzog; Sonja Wegener; Kostyantyn Holubyev
Journal:  Radiat Oncol       Date:  2017-05-25       Impact factor: 3.481

2.  Review of in vivo optical molecular imaging and sensing from x-ray excitation.

Authors:  Brian W Pogue; Rongxiao Zhang; Xu Cao; Jeremy Mengyu Jia; Arthur Petusseau; Petr Bruza; Sergei A Vinogradov
Journal:  J Biomed Opt       Date:  2021-01       Impact factor: 3.170

3.  Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy.

Authors:  Dong Zhou; Hui Zhang; Peiqing Ye
Journal:  Comput Math Methods Med       Date:  2016-01-19       Impact factor: 2.238

4.  Comparison of stereotactic plans for brain tumors with two different multileaf collimating systems.

Authors:  Livia Marrazzo; Margherita Zani; Stefania Pallotta; Daniela Greto; Silvia Scoccianti; Cinzia Talamonti; Giampaolo Biti; Marta Bucciolini
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.