Literature DB >> 10435708

Intraluminal irradiation for TIPS stenosis: preliminary results in a swine model.

T Lessie1, H C Yoon, H A Nelson, D J Fillmore, G N Baldwin, F J Miller.   

Abstract

PURPOSE: To evaluate the ability of 32phosphorus intraluminal irradiation to reduce pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt (TIPS).
MATERIALS AND METHODS: TIPS were successfully placed in 11 swine with normal portal pressures. Six animals received 15.2 Gy intraluminal irradiation to the hepatic parenchyma and venous outflow tract at the time of TIPS placement with use of a NA32P-filled balloon angioplasty catheter. Five control animals underwent TIPS and balloon angioplasty with saline. All animals were followed up for 28 days, at which time percutaneous portography was performed, the animals were killed, and the tissue around the TIPS stent was processed for histologic analysis. Maximum pseudointimal hyperplasia as a percentage of estimated TIPS diameter was calculated for each animal.
RESULTS: At the time of euthanasia, all five control TIPS and all but one irradiated TIPS were occluded. Histologic analysis demonstrated considerable variability in the degree of pseudointimal hyperplasia within each TIPS and between animals. No statistically significant difference was found in the maximum pseudointimal hyperplasia, measured as a percentage of stent radius, between control (80.2%+/-17.4%) and irradiated animals (69.2%+/-25.2%).
CONCLUSIONS: Irradiation of TIPS with 15.2 Gy 32P delivered at the time of TIPS placement did not significantly improve TIPS patency or reduce the degree of pseudointimal hyperplasia in swine with normal portal pressures.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10435708     DOI: 10.1016/s1051-0443(99)70135-1

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  3 in total

1.  Covered stents in transjugular portosystemic shunt: healing response to non-porous ePTFE covered stent grafts with and without intraluminal irradiation.

Authors:  Klaus A Hausegger; Horst Portugaller; Nicolas P Macri; Josef Tauss; Peter Schedlbauer; Johannes Deutschmann; Georg Stücklschweiger; Heidi Stranzl
Journal:  Eur Radiol       Date:  2002-10-31       Impact factor: 5.315

2.  Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudo-intimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model.

Authors:  Tae Seok Seo; Joo Hyeong Oh; Young Koo Park; Ho Young Song; Sang Joon Park; Sun Hong Yuk
Journal:  Korean J Radiol       Date:  2005 Oct-Dec       Impact factor: 3.500

3.  Effects of intraluminal irradiation with Holmium-166 for TIPS stenosis: experimental study in a swine model.

Authors:  Ji Seon Park; Joo Hyeong Oh; Deog Yoon Kim; Yong Koo Park; Sang Joon Park; Soo Joong Kim
Journal:  Korean J Radiol       Date:  2007 Mar-Apr       Impact factor: 3.500

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.