Characterization and use of a commercial n-type diode system.

T Wolff1, S Carter, K A Langmack, N I Twyman, P P Dendy.   

Abstract

The characteristics of n-type diodes (linearity, temperature, dose rate, radiation damage response, directional dependence, output factors, wedge factors and percentage depth dose determinations) were investigated. Subsequently, the diodes were used clinically for in vivo dose verification during external megavoltage photon beam therapy. It has been shown that n-type diodes are easy to use and the results obtained are comparable to those reported for p-type diodes. On most occasions, n-type diodes can be used without any additional correction factors apart from regular monthly calibration. There is good agreement between the uncertainty limits estimated from the diodes' characteristics and those obtained on the basis of 2261 patient measurements.

Entities:  

Mesh:

Year:  1998        PMID: 10434912     DOI: 10.1259/bjr.71.851.10434912

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  COTS Silicon diodes as radiation detectors in proton and heavy charged particle radiotherapy 1.

Authors:  Franz-Joachim Kaiser; Niels Bassler; Oliver Jäkel
Journal:  Radiat Environ Biophys       Date:  2010-06-13       Impact factor: 1.925

2.  Evaluation of off-axis wedge correction factor using diode dosimeters for estimation of delivered dose in external radiotherapy.

Authors:  Mahmoud Allahverdi; Alireza Mohammadkarim; Mahbod Esfehani; Hasanali Nedaie; Alireza Shirazi; Ghazale Geraily
Journal:  J Med Phys       Date:  2012-01

3.  Evaluating the Impact of Various Parameters on the Gamma Index Values of 2D Diode Array in IMRT Verification.

Authors:  Keyvan Jabbari; Fakhereh Pashaei; Mohammad R Ay; Alireza Amouheidari; Mohammad B Tavakoli
Journal:  J Med Signals Sens       Date:  2018 Jan-Mar

4.  "Characterization of ELEKTA SRS cone collimator using high spatial resolution monolithic silicon detector array".

Authors:  Khalsa Al Shukaili; Stéphanie Corde; Marco Petasecca; Vladimir Pereveratylo; Michael Lerch; Michael Jackson; Anatoly Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2018-05-22       Impact factor: 2.102

5.  Characterization of an in vivo diode dosimetry system for clinical use.

Authors:  Kai Huang; William S Bice; Oscar Hidalgo-Salvatierra
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

6.  Interplay effect of angular dependence and calibration field size of MapCHECK 2 on RapidArc quality assurance.

Authors:  Hosang Jin; Vance P Keeling; Daniel A Johnson; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102