Literature DB >> 10434389

Early detection of upper airway obstructions by analysis of acoustical respiratory input impedance.

S Reisch1, H Steltner, J Timmer, C Renotte, J Guttmann.   

Abstract

Repetitive occurrence of partial or total upper airway obstruction characterizes several respiratory dysfunctions such as the obstructive sleep apnea syndrome (OSAS). In OSAS patients, pharyngeal collapses are linked to a decrease in upper airway muscle activity during sleep which causes decreased upper airway wall stiffness. Continuous positive airway pressure (CPAP) is recommended as the treatment of choice. Advancements in CPAP therapy require early detection of respiratory events in real time to adapt the level of the applied pressure to airway collapsibility. The forced oscillation technique (FOT) is a noninvasive method which reflects patients' airway patency by measuring respiratory impedance. The aim of this study was to evaluate by a mathematical model of the respiratory system if FOT can provide an early detection index of total or partial upper airway obstruction. Furthermore, the simulation should suggest which characteristic features are relevant for early apnea detection in measured clinical data. The respiratory system has been treated as a series of cylindrical segments. The oropharynx analog of the model allows simulation of upper airway collapse, mimicking the situation in patients with OSAS. We calculated the input impedance for different degrees of upper airway obstruction ranging from unobstructed airways to total occlusion. Furthermore, we simulated different upper airway wall compliances. We compared the simulation with real data. The results of the study suggest that FOT is a valuable tool for assessing the degree of upper airway obstruction in patients with OSAS. Especially, the phase angle of the impedance seems to be a potentially useful tool for early apnea detection by assessing the upper airway wall collapsibility.

Entities:  

Mesh:

Year:  1999        PMID: 10434389     DOI: 10.1007/s004220050542

Source DB:  PubMed          Journal:  Biol Cybern        ISSN: 0340-1200            Impact factor:   2.086


  3 in total

1.  The diagnosis value and its implication of impulse oscillometry in obstructive sleep apnea syndrome patients.

Authors:  H Liu; W Ni; J Zhao; S Xiong; Y Xu; Z Zhang
Journal:  J Tongji Med Univ       Date:  2000

2.  Early Diagnosis of Respiratory Abnormalities in Asbestos-Exposed Workers by the Forced Oscillation Technique.

Authors:  Paula Morisco de Sá; Hermano Albuquerque Castro; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  PLoS One       Date:  2016-09-09       Impact factor: 3.240

3.  Forced oscillation technique for early detection of the effects of smoking and COPD: contribution of fractional-order modeling.

Authors:  Caroline Oliveira Ribeiro; Alvaro Camilo Dias Faria; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2018-10-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.