Literature DB >> 10432083

Stereotactic breast biopsy in a community hospital setting.

D Klem1, H K Jacobs, R Jorgensen, L S Facenda, D A Baker, A Altimari.   

Abstract

Our institution began using a stereotactic core needle breast biopsy system for mammographically detected breast lesions in November 1996. The system consists of a LORAD stereo imaging table and an 11-gauge vacuum-assisted mammotome (Biopsys Medical, Irvine, CA). All biopsies were performed with the combined efforts of a radiologist and a surgeon. Three hundred sixteen biopsies were attempted in 279 patients, with multiple biopsies in 31 patients. Indications included microcalcifications in 52 per cent of patients and a mass in 48 per cent of patients. Biopsy was unsuccessful in 20 patients (6.3%). Pathologic diagnoses included invasive ductal carcinoma (19 patients), invasive lobular carcinoma (2), ductal carcinoma in situ (17), atypical ductal hyperplasia (8), atypical lobular hyperplasia (1), fibroadenoma (40), lymph node (7), and benign (202). Invasive cancer, in situ carcinoma, or atypical hyperplasia was diagnosed in 46 (15.6%) lesions. Thirty-six patients had open biopsies. The core biopsy diagnosis was correct in 27 lesions, unable to be confirmed in six cases and changed in four cases, with three lesions upgraded and one case downgraded. The 11-gauge vacuum-assisted mammotome provides excellent accuracy for diagnosing mammographic abnormalities. A combined effort between radiology and surgical services is an effective way of using the stereotactic biopsy system.

Entities:  

Mesh:

Year:  1999        PMID: 10432083

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  3 in total

1.  Mammotome: less invasive than ABBI with similar accuracy for early breast cancer detection.

Authors:  Walter P Weber; Rosanna Zanetti; Igor Langer; Sophie Dellas; Markus Zuber; Holger Moch; Eugenia Remmel; Daniel Oertli; Edward Wight; Walter R Marti
Journal:  World J Surg       Date:  2005-04       Impact factor: 3.352

2.  Efficacy and cost-effectiveness of stereotactic vacuum-assisted core biopsy of nonpalpable breast lesions: analysis of 602 biopsies performed over 5 years.

Authors:  A Luparia; M Durando; P Campanino; E Regini; D Lucarelli; A Talenti; G Mattone; G Mariscotti; A Sapino; G Gandini
Journal:  Radiol Med       Date:  2011-01-12       Impact factor: 3.469

3.  Feasibility and safety of image-guided vacuum-assisted breast biopsy: A PRISMA-compliant systematic review and meta-analysis of 20 000 population from 36 longitudinal studies.

Authors:  Ming Fang; Guilin Liu; Guoliang Luo; Tianyu Wu
Journal:  Int Wound J       Date:  2019-09-18       Impact factor: 3.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.