Literature DB >> 10430152

CT angiography with volume rendering for quantifying vascular stenoses: in vitro validation of accuracy.

B S Kuszyk1, D G Heath, P T Johnson, J Eng, E K Fishman.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the accuracy of CT angiography with volume rendering for quantifying vascular stenoses in vitro.
MATERIALS AND METHODS: Vascular models with three degrees of stenosis (33%, 67%, and 83%) were imaged at three orientations to the axial plane (parallel, perpendicular, or 45 degrees ) using helical CT with 2-mm collimation and two pitches (1 or 2), two reconstruction intervals (1 or 2 mm), and two scan times (.75 or 1 sec). Diameter and percentage of stenosis were measured from volume renderings using full width at half maximum. Images were measured in two planes whenever resolution varied with direction. Statistical analysis was performed using analysis of variance.
RESULTS: Mean absolute error of the measured percentage of stenosis was 7% (range, 0-27%). The actual percentage of stenosis and vessel orientation had the most significant effects on accuracy (p < .001). The measured percentage of stenosis was significantly less accurate with phantoms parallel to the axial plane than with other orientations (p < .001). Mean absolute error in the measured percentage of stenosis was 4% when the parallel-to-the-axial-plane orientation was excluded. Overlapping (1-mm) reconstructions were significantly more accurate than 2-mm reconstructions (p < .05) and direction of measurement significantly affected accuracy (p < .05), but these effects were secondary.
CONCLUSION: CT angiography with volume rendering can accurately quantify vascular stenoses, but it is less accurate for vessels in the axial plane. With 2-mm collimation, vessel characteristics have greater effects on accuracy than do acquisition parameters.

Mesh:

Year:  1999        PMID: 10430152     DOI: 10.2214/ajr.173.2.10430152

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  Application of CT angiography of complex cerebrovascular lesions during surgical decision making.

Authors:  Ying Chen; Wayne Manness; Keith Kattner
Journal:  Skull Base       Date:  2004-11

2.  Intracranial vascular stenosis and occlusive disease: evaluation with CT angiography, MR angiography, and digital subtraction angiography.

Authors:  Suzie Bash; J Pablo Villablanca; Reza Jahan; Gary Duckwiler; Monica Tillis; Chelsea Kidwell; Jeffrey Saver; James Sayre
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

3.  Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography.

Authors:  J Pablo Villablanca; Reza Jahan; Parizad Hooshi; Silvester Lim; Gary Duckwiler; Aman Patel; James Sayre; Neil Martin; John Frazee; John Bentson; Fernando Viñuela
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

4.  Coronary vessel wall evaluation by magnetic resonance imaging in the multi-ethnic study of atherosclerosis: determinants of image quality.

Authors:  Ashkan A Malayeri; Robson Macedo; Debiao Li; Shaoguang Chen; Hossein Bahrami; Shenghan Lai; João A C Lima; David A Bluemke
Journal:  J Comput Assist Tomogr       Date:  2009 Jan-Feb       Impact factor: 1.826

5.  Multidetector CT angiography and 3D reconstruction in young children with coarctation of the aorta.

Authors:  Xi-Hong Hu; Guo-Ying Huang; Mier Pa; Xin Li; Lin Wu; Fang Liu; Bing Jia; Guo-Ping Li
Journal:  Pediatr Cardiol       Date:  2008-05-15       Impact factor: 1.655

Review 6.  Treatment and imaging of intracranial atherosclerotic stenosis: current perspectives and future directions.

Authors:  Ido R van den Wijngaard; Ghislaine Holswilder; Marianne A A van Walderveen; Ale Algra; Marieke J H Wermer; Osama O Zaidat; Jelis Boiten
Journal:  Brain Behav       Date:  2016-08-31       Impact factor: 2.708

7.  Comparison of high-resolution MRI with CT angiography and digital subtraction angiography for the evaluation of middle cerebral artery atherosclerotic steno-occlusive disease.

Authors:  Qi Liu; Jun Huang; Andrew J Degnan; Shiyue Chen; Jonathan H Gillard; Zhongzhao Teng; Jianping Lu
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-19       Impact factor: 2.357

  7 in total