Literature DB >> 10428341

Pulmonary arterial Doppler velocimetry in fetuses with lung hypoplasia.

R Chaoui1, K Kalache, C Tennstedt, F Lenz, M Vogel.   

Abstract

OBJECTIVE: The aim of the study was to examine Doppler flow velocity waveforms in the main stems of the pulmonary arteries in fetuses with autopsy-proven lung hypoplasia and to find out whether in these conditions typical patterns can be found. STUDY
DESIGN: Doppler spectra were derived from the main stem of the right or left pulmonary artery in fetuses at high-risk for lung-hypoplasia. The following Doppler parameters were analyzed and compared to reference ranges: peak systolic velocity, acceleration time, time velocity integral, end-systolic reverse flow, pulsatility index (PI). Pulmonary hypoplasia was found in nine cases at autopsy after termination of pregnancy (19-23 weeks). According to etiology, three groups were considered: (A) bilateral renal malformations (n=4), (B) congenital diaphragmatic hernia (n=2), and (C) miscellaneous malformations including heart defects (n=3).
RESULTS: The following Doppler parameters were found: normal values in end-systolic reversal flow in all cases, decreased peak systolic velocity and acceleration time in 3/9, decreased time velocity integral in 4/9 and increased pulsatility index in 6/9. Considering the etiology of pulmonary hypoplasia the pulsatility index was found to be the most sensitive, since all fetuses in groups A and B had an abnormal PI.
CONCLUSIONS: Human fetuses with renal malformations and diaphragmatic hernia associated with lung hypoplasia show as early as 19-23 weeks of gestation an abnormal Doppler spectrum in the main stems of the pulmonary arteries. Increased PI is the best parameter to detect flow abnormality in this condition. Since the Doppler spectrum depends on cardiac anatomy and function, PI in lung hypoplasia seems to be reliable only when cardiac defects are absent.

Entities:  

Mesh:

Year:  1999        PMID: 10428341     DOI: 10.1016/s0301-2115(98)00327-3

Source DB:  PubMed          Journal:  Eur J Obstet Gynecol Reprod Biol        ISSN: 0301-2115            Impact factor:   2.435


  7 in total

1.  Correlation between US and MRI for prenatal lung volumetry in diaphragmatic hernia, and use of Doppler to identify the ipsilateral lung cap.

Authors:  Amparo Castellote; Sandra Mencho; Elena Carreras; Teresa Higueras; Lina Cadavid; Joaquim Piqueras; Goya Enriquez
Journal:  Pediatr Radiol       Date:  2011-09-22

2.  Can fetal pulmonary artery Doppler indices predict neonatal respiratory distress syndrome?

Authors:  G A F A Moety; H M Gaafar; N M El Rifai
Journal:  J Perinatol       Date:  2015-10-22       Impact factor: 2.521

Review 3.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

4.  Fetal preload index of the inferior vena cava and neonatal outcome of congenital diaphragmatic hernia.

Authors:  Hiroshi Miura; Masaki Ogawa; Akira Sato; Jun Fukuda; Toshinobu Tanaka
Journal:  J Med Ultrason (2001)       Date:  2009-06-17       Impact factor: 1.314

Review 5.  Bronchopulmonary foregut malformations: embryology, radiology and quandary.

Authors:  N A Barnes; D W Pilling
Journal:  Eur Radiol       Date:  2003-02-12       Impact factor: 5.315

6.  Pulmonary artery blood flow patterns in fetuses with pulmonary outflow tract obstruction.

Authors:  S Peyvandi; J Rychik; M McCann; D Soffer; Z Tian; A Szwast
Journal:  Ultrasound Obstet Gynecol       Date:  2014-03       Impact factor: 7.299

7.  Improved pulmonary function in the nitrofen model of congenital diaphragmatic hernia following prenatal maternal dexamethasone and/or sildenafil.

Authors:  Carmen Mesas Burgos; Erik G Pearson; Marcus Davey; John Riley; Huimin Jia; Pablo Laje; Alan W Flake; William H Peranteau
Journal:  Pediatr Res       Date:  2016-07-04       Impact factor: 3.756

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.