| Literature DB >> 10427766 |
H Nakakuki1, H Horie, Y Yamauchi, K Kohata.
Abstract
We have developed a new high-performance liquid chromatography (HPLC) method for the analysis of methylated xanthines in tea by removing polyphenols using a polyvinylpolypyrroridone (PVPP) pre-column. The PVPP pre-column was connected with the upstream of analytical column to remove catechins in tea extract. Using this pre-column, caffeine and theobromine in tea, which belong to methylated xanthines, could be rapidly determined in less than 10 min with an isocratic solvent system. RSDs of standard solutions of caffeine and theobromine were about 0.3 and 0.3% for the retention time, and were about 1.6 and 2.5% for the peak area. The quantitation curves of caffeine and theobromine were linear from 5 to over 1000 ng.Entities:
Mesh:
Substances:
Year: 1999 PMID: 10427766 DOI: 10.1016/s0021-9673(99)00418-5
Source DB: PubMed Journal: J Chromatogr A ISSN: 0021-9673 Impact factor: 4.759