Literature DB >> 10422240

Trace level detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by microimmunosensor.

P T Charles1, A W Kusterbeck.   

Abstract

Reported in this paper is the development and characterization of a highly sensitive microcapillary immunosensor for the detection of the explosive, hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). The immunosensor exploits antibodies as recognition elements for target antigens, fluorescence dye conjugates for reporter molecules and fused silica microcapillaries for its high surface-to-volume ratio. Detection of RDX with the microcapillary immunosensor requires covalent immobilization of anti-RDX antibodies on the inner core of the microcapillaries via heterobifunctional cross-linker chemistry. Subsequent saturation of all antibody binding domains follows with a synthetically prepared fluorescent analog of RDX. Displacement immunoassays were performed with the microcapillary immunosensor with the injection of unlabeled RDX at concentration levels from 1 part-per-trillion (pptr) to 1000 part-per-billion (ppb). As unlabeled RDX reaches the binding domain of the antibody, fluorescent RDX analog is displaced from the antibody, flows downstream and is measured by a spectrofluorometer. Fluorescence measurements of the displaced fluorescent RDX analog were equated to a standard calibration curve to quantify sample concentration. Complete evaluation of the RDX microcapillary immunosensor for selectivity and sensitivity was performed based on the following criteria: variable flow rates, antibody cross-reactivity, reproducibility and cross-linker (carbon spacer) comparison. Results indicate the lowest detectable limit (LDL) for RDX is 10 pptr (ng/l) with a linear dynamic range from 0.1 to 1000 ppb (ug/l).

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10422240     DOI: 10.1016/s0956-5663(99)00009-3

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Perylene Diimide Based Fluorescent Dyes for Selective Sensing of Nitroaromatic Compounds: Selective Sensing in Aqueous Medium Across Wide pH Range.

Authors:  P S Hariharan; J Pitchaimani; Vedichi Madhu; Savarimuthu Philip Anthony
Journal:  J Fluoresc       Date:  2015-11-20       Impact factor: 2.217

2.  Fluorescence-based sensing of 2,4,6-trinitrotoluene (TNT) using a multi-channeled poly(methyl methacrylate) (PMMA) microimmunosensor.

Authors:  Paul T Charles; Andre A Adams; Peter B Howell; Scott A Trammell; Jeffrey R Deschamps; Anne W Kusterbeck
Journal:  Sensors (Basel)       Date:  2010-01-22       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.