Literature DB >> 10421392

Trace element contamination of total parenteral nutrition. 1. Contribution of component solutions.

M M Pluhator-Murton1, R N Fedorak, R J Audette, B J Marriage, R W Yatscoff, L M Gramlich.   

Abstract

BACKGROUND: Trace elements have been shown to contaminate total parenteral nutrition (TPN) solutions.
METHODS: This study used the multi-elemental technology of inductively coupled plasma-mass spectrometry to demonstrate the extent to which trace elements were present in amounts above (ie, as contaminants) or below expected levels in eight TPN component solutions.
RESULTS: Of the 66 trace elements scanned, there were 12 trace element contaminants in amounts >1 microg/L (zinc, copper, manganese, chromium, selenium, boron, aluminum, titanium, barium, vanadium, arsenic, and strontium) in the eight component solutions studied. Trace element contaminants were present in all solutions, and different trace elements contaminated the solutions at various concentrations. Component solutions of amino acid, potassium chloride, calcium gluconate, and sodium chloride contained the greatest numbers of trace element contaminants, whereas the lowest numbers were present in sterile water and magnesium sulfate. Interlot and intermanufacturer variations were apparent. Measured concentrations of trace elements in the multi-trace element additive solution also were higher than the labeled values. A comparison of the amounts of contaminated trace elements delivered by a typical TPN mixture relative to the amounts typically absorbed by the gastrointestinal tract indicates that the inadvertent delivery of trace elements from contaminated TPN solutions may be substantial.
CONCLUSIONS: All eight components tested were contaminated with trace elements not intended to be present in the product, and similarly, the multi-trace element component contained trace elements either above or below that which the label claimed.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10421392     DOI: 10.1177/0148607199023004222

Source DB:  PubMed          Journal:  JPEN J Parenter Enteral Nutr        ISSN: 0148-6071            Impact factor:   4.016


  8 in total

Review 1.  Advances in Trace Element Supplementation for Parenteral Nutrition.

Authors:  Patti Perks; Emily Huynh; Karolina Kaluza; Joseph I Boullata
Journal:  Nutrients       Date:  2022-04-23       Impact factor: 6.706

2.  Exploring titanium(IV) chemical proximity to iron(III) to elucidate a function for Ti(IV) in the human body.

Authors:  Manoj Saxena; Sergio A Loza-Rosas; Kavita Gaur; Shweta Sharma; Sofia C Pérez Otero; Arthur D Tinoco
Journal:  Coord Chem Rev       Date:  2018-03-20       Impact factor: 22.315

3.  Physical stability of an all-in-one parenteral nutrition admixture for preterm infants upon mixing with micronutrients and drugs.

Authors:  Vigdis Staven; Siri Wang; Ingrid Grønlie; Ingunn Tho
Journal:  Eur J Hosp Pharm       Date:  2018-07-07

4.  Continuous venovenous hemodiafiltration trace element clearance in pediatric patients: a case series.

Authors:  Deborah A Pasko; Mariann D Churchwell; Imad F Btaiche; Jinesh C Jain; Bruce A Mueller
Journal:  Pediatr Nephrol       Date:  2009-01-21       Impact factor: 3.714

Review 5.  Trace Elements in Parenteral Nutrition: Considerations for the Prescribing Clinician.

Authors:  Jennifer Jin; Leanne Mulesa; Mariana Carrilero Rouillet
Journal:  Nutrients       Date:  2017-04-28       Impact factor: 5.717

6.  Calcium chloride in neonatal parenteral nutrition: compatibility studies using laser methodology.

Authors:  Robert K Huston; J Mark Christensen; Chanida Karnpracha; Jill E Rosa; Sara M Clark; Evelyn A Migaki; YingXing Wu
Journal:  PLoS One       Date:  2014-09-05       Impact factor: 3.240

7.  Characterization and Separation Performance of a Novel Polyethersulfone Membrane Blended with Acacia Gum.

Authors:  Yehia Manawi; Viktor Kochkodan; Ebrahim Mahmoudi; Daniel J Johnson; Abdul Wahab Mohammad; Muataz Ali Atieh
Journal:  Sci Rep       Date:  2017-11-20       Impact factor: 4.379

Review 8.  Parenteral trace element provision: recent clinical research and practical conclusions.

Authors:  P Stehle; B Stoffel-Wagner; K S Kuhn
Journal:  Eur J Clin Nutr       Date:  2016-04-06       Impact factor: 4.016