Literature DB >> 10416417

A mechanical distal aiming device for distal locking in femoral nails.

C Krettek1, B Könemann, T Miclau, R Kölbli, T Machreich, H Tscherne.   

Abstract

Although the free hand technique remains the most popular method for distal interlocking screw insertion, proximally mounted radiation independent devices that compensate for implant deformation recently have been developed for the femur. However, the benefits of such systems have not been determined. This study prospectively compared the duration of the nailing procedure, the length of radiation time, and the accuracy of interlocking screw placement when using a radiation independent distal aiming system with those using the free hand technique. In 20 paired intact anatomic specimen femurs, one surgeon experienced only in the free hand technique performed statically locked intramedullary nailing using the two methods. For the aiming system and free hand technique, respectively, the total operation time was 19.1 +/- 8.4 minutes versus 20.9 +/- 11.3 minutes, the distal locking time was 6.6 +/- 2.4 minutes versus 4.8 +/- 1.5 minutes, the total fluoroscopy time was 23 +/- 17 seconds versus 69 +/- 34 seconds, and the distal locking fluoroscopy time was 0 versus 37 +/- 15.5 seconds. There were no failures in either group. Drill nail contact and distal screw damage were greater with the free hand technique. This study suggests that the main advantages of the aiming arm compared with the free hand technique include the elimination of radiation during distal interlocking and more precise screw placement with decreased insertion related hardware damage.

Entities:  

Mesh:

Year:  1999        PMID: 10416417     DOI: 10.1097/00003086-199907000-00033

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  [Clinical results with A new retrograde femoral nail with a radiographical-free proximal locking device. A prospective study with 50 fractures].

Authors:  B Friemert; P Keppler; F von Lübken; C Willy; L Claes; H Gerngross; D Wörz
Journal:  Unfallchirurg       Date:  2005-03       Impact factor: 1.000

2.  Nail over nail technique for distal locking of femoral intramedullary nails.

Authors:  Rajesh Rohilla; Roop Singh; Narender Magu; Ashish Devgun; Ramchander Siwach; Ashish Gulia
Journal:  Int Orthop       Date:  2008-05-24       Impact factor: 3.075

3.  Surgical technique: static intramedullary nailing of the femur and tibia without intraoperative fluoroscopy.

Authors:  Neil J White; Anthony T Sorkin; Geoffrey Konopka; Todd O McKinley
Journal:  Clin Orthop Relat Res       Date:  2011-03-03       Impact factor: 4.176

4.  Preliminary Results with the Shape Memory Nail: A Self-contained Distal Locking Mechanism for Diaphyseal Femur Fractures.

Authors:  Nando Ferreira; Luan Nieuwoudt
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 Sep-Dec

5.  Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.

Authors:  Markus Windolf; Josh Schroeder; Ladina Fliri; Benno Dicht; Meir Liebergall; R Geoff Richards
Journal:  BMC Musculoskelet Disord       Date:  2012-01-25       Impact factor: 2.362

6.  C-Arm Image-Based Surgical Path Planning Method for Distal Locking of Intramedullary Nails.

Authors:  Wei-En Hsu; Ching-Hsiao Yu; Chih-Ju Chang; Hung-Kang Wu; Tsong-Han Yu; Ching-Shiow Tseng
Journal:  Appl Bionics Biomech       Date:  2018-05-23       Impact factor: 1.781

7.  A New Accurate, Simple and Less Radiation Exposure Device for Distal Locking of Femoral Intramedullary Nails.

Authors:  Gang Wang; Baojun Wang; Hua Gao; Zhenyu Liu
Journal:  Int J Gen Med       Date:  2021-08-04
  7 in total