Literature DB >> 10416415

The osseous response to corundum blasted implant surfaces in a canine hip model.

S A Hacking1, J D Bobyn, M Tanzer, J J Krygier.   

Abstract

The purpose of this study was to examine the radiographic and histologic response to corundum blasted implant surfaces of varying roughness in a canine total hip arthroplasty model. Three types of tapered femoral implants were made from titanium alloy and were identical in every respect except surface finish. The entire surface of the femoral implant had a 2.9-, 4.2-, or 6.7-micron average surface roughness (Ra) from blasting with 60-, 24-, or 16-grit corundum particles, respectively. Twenty-two stems in 11 dogs were evaluated at 6 months. Twenty-one of the stems showed osseointegration, whereas in one stem a fibrous interface developed. Abundant new periimplant bone formation occurred, particularly within the intramedullary canal where trabeculae spanned implant to endosteal cortex gaps as large as 5 mm. Bone apposition with the 60-, 24-, and 16-grit stems averaged 31.7%, 32%, and 27.9%, respectively; the differences were not statistically significant. However, the pattern of new bone formation was different in that the average length of each region of bone apposition for the 60- and 24-grit surfaces was 50% greater than that for the coarser 16-grit surface. The observations of this study indicate that because of their highly osteoconductive nature, corundum blasted surfaces represent an important and valuable technology for the design of noncemented implants.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10416415     DOI: 10.1097/00003086-199907000-00031

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  8 in total

Review 1.  Calcium Phosphate Bioceramics: A Review of Their History, Structure, Properties, Coating Technologies and Biomedical Applications.

Authors:  Noam Eliaz; Noah Metoki
Journal:  Materials (Basel)       Date:  2017-03-24       Impact factor: 3.623

2.  Enhanced cell integration to titanium alloy by surface treatment with microarc oxidation: a pilot study.

Authors:  Young Wook Lim; Soon Yong Kwon; Doo Hoon Sun; Hyoun Ee Kim; Yong Sik Kim
Journal:  Clin Orthop Relat Res       Date:  2009-05-12       Impact factor: 4.176

3.  Radiostereometric analysis: the hip.

Authors:  F Bottner; E Su; B Nestor; B Azzis; T P Sculco; M Bostrom
Journal:  HSS J       Date:  2005-09

4.  Direct visualization and quantification of bone growth into porous titanium implants using micro computed tomography.

Authors:  E Baril; L P Lefebvre; S A Hacking
Journal:  J Mater Sci Mater Med       Date:  2011-04-22       Impact factor: 3.896

5.  Bone growth enhancement in vivo on press-fit titanium alloy implants with acid etched microtexture.

Authors:  Henrik Daugaard; Brian Elmengaard; Joan E Bechtold; Kjeld Soballe
Journal:  J Biomed Mater Res A       Date:  2008-11       Impact factor: 4.396

6.  Osseous integration in porous tantalum implants.

Authors:  Christos G Paganias; George A Tsakotos; Stephanos D Koutsostathis; George A Macheras
Journal:  Indian J Orthop       Date:  2012-09       Impact factor: 1.251

7.  Biocompatibility and osteogenic properties of porous tantalum.

Authors:  Qian Wang; Hui Zhang; Qijia Li; Lei Ye; Hongquan Gan; Yingjie Liu; Hui Wang; Zhiqiang Wang
Journal:  Exp Ther Med       Date:  2015-01-23       Impact factor: 2.447

8.  Biological Safety Evaluation and Surface Modification of Biocompatible Ti-15Zr-4Nb Alloy.

Authors:  Yoshimitsu Okazaki; Shin-Ichi Katsuda
Journal:  Materials (Basel)       Date:  2021-02-04       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.