Literature DB >> 10415085

High sensitivity immunoassays using particulate fluorescent labels.

M Hall1, I Kazakova, Y M Yao.   

Abstract

The use of polystyrene fluorescent microspheres as sensitive labels in direct-detection (not enzymatically amplified) heterogeneous equilibrium "sandwich" immunoassays in 96-well plates is described. With mouse IgG as a model antigen, a fluorescent particulate label is more sensitive than a corresponding soluble reporter. The limit of detection of mouse IgG in the multiparametrically optimized assay was 0.2 ng/ml (7.6 x 10(8) antigens/ml) for the particulate reporter and 50 ng/ml (1.9 x 10(11) antigens/ml) for the soluble reporter. The sensitivities of assays using the particulate label were dependent on the surface densities of the capture and reporter antibodies and the concentration of reporter beads. Sensitivity was improved by adding the preformed reporter antibody/fluorescent microsphere complex to trapped antigen on the well surfaces instead of sequentially adding the reporter antibody and then the fluorescent microspheres. Maximal (equilibrium) binding of the particulate reporter to captured antigen occurred after 20 h with a concentration of 1.4 x 10(9) reporter beads/ml. Thus, particulate fluorescent labels provide high sensitivity in direct-detection immunoassays. Copyright 1999 Academic Press.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10415085     DOI: 10.1006/abio.1999.4155

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

1.  Accurate sensitivity of quantum dots for detection of HER2 expression in breast cancer cells and tissues.

Authors:  Akram-Sadat Tabatabaei-Panah; Mahmood Jeddi-Tehrani; Roya Ghods; Mohammad-Mehdi Akhondi; Nazanin Mojtabavi; Ahmad-Reza Mahmoudi; Ebrahim Mirzadegan; Sorour Shojaeian; Amir-Hassan Zarnani
Journal:  J Fluoresc       Date:  2012-12-05       Impact factor: 2.217

2.  Design Considerations for CMOS-Integrated Hall-Effect Magnetic Bead Detectors for Biosensor Applications.

Authors:  K Skucha; S Gambini; P Liu; M Megens; J Kim; Be Boser
Journal:  J Microelectromech Syst       Date:  2013-06-05       Impact factor: 2.417

3.  Study on extracellular matrix metalloproteinase inducer and human epidermal growth factor receptor-2 protein expression in papillary thyroid carcinoma using a quantum dot-based immunofluorescence technique.

Authors:  Tian Tang; Duan-Lian Zhang
Journal:  Exp Ther Med       Date:  2015-02-12       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.