[A new diagnostic concept in cardiac pacing for the evaluation of the incidence of atrial arrhythmias. Results of the AIDA study].

P Defaye1, E Mouton.   

Abstract

An international, prospective, multicentre trial (AIDA) was undertaken from October 1995 to March 1997. The object was to compare the diagnosis of atrial arrhythmias (AA) by the automatic interpretation of the memory functions of dual chamber pacemakers with that of 24 hour Holter monitoring at day 1. The second objective was to assess the incidence and symptomatology of the AA during follow-up at Day 28. In France, 226 patients implanted with Chorus, Chorus II and Chorus RM pacemakers were included in the study (148 men, 70.5 +/- 10.8 years) for the following indications: AVB (atrioventricular block)/bundle branch block (47.3%), sinus mode dysfunction (10.2%), bradycardia-tachycardia syndrome (10.2%), AVB + sinus node dysfunction + cardia-tachycardia syndrome (19.5%), other (2.2%). AA were documented in 34.5% of patients before implantation. Of the 226 patients analysed at Day 1, 23 (10.2%) had at least one episode of AA diagnosed simultaneously by Holter monitoring and the automatic interpretation (AIDA). These AA were atrial fibrillation (15 patients), atrial flutter (2 patients) and atrial tachycardia (6 patients). The sensitivity of the AIDA programme for detecting AA was 92% and the specificity 97%. Of the 156 patients evaluated at Day 28, the programme diagnosed AA in 78 patients (50%), 34 of which (21.8%) were asymptomatic and without previously documented AA. The results of the AIDA study confirmed the excellent sensitivity and specificity of the memory functions of these cardiac pacemakers for analysis of AA. They seem to be very common during the follow-up of pacemaker-equipped patients. This new diagnostic concept will facilitate the programming and study of the efficacy of anti-arrhythmic therapy prescribed during long-term follow-up.

Entities:  

Mesh:

Year:  1999        PMID: 10410810

Source DB:  PubMed          Journal:  Arch Mal Coeur Vaiss        ISSN: 0003-9683


  2 in total

Review 1.  Rationale and patient selection for "hybrid" drug and device therapy in atrial and ventricular arrhythmias.

Authors:  A John Camm; Irina Savelieva
Journal:  J Interv Card Electrophysiol       Date:  2003-10       Impact factor: 1.900

2.  Pacemaker prevention therapy in drug-refractory paroxysmal atrial fibrillation: reliability of diagnostics and effectiveness of prevention pacing therapy in Vitatron selection device.

Authors:  Paolo Terranova; Paolo Valli; Peppino Terranova; Simonetta Dell'Orto; Enrico Maria Greco
Journal:  Indian Pacing Electrophysiol J       Date:  2006-04-01