[Measuring intraoperative radiation exposure of the trauma surgeon. Measuring eye, thyroid gland and hand with highly sensitive thermoluminescent detectors].

M Fuchs1, H Modler, A Schmid, C Dumont, K M Stürmer.   

Abstract

A prospective study of 24 operative procedures involving minimal invasive techniques and fluoroscopic guidance was undertaken in order to measure the radiation exposure to the primary surgeon. Radiation was monitored with the use of high sensitive thermoluminescent dosimeters. At the spots of dosimetry (eyes, thyroid gland, hand and genitals under lead apron) the dose was uniformly low and ranged from 0.6 muSv at the eyes to 259.3 muSv at the hand. The dose is determined by the duration of fluoroscopy and the amount of scattered rays, which in turn depends on the volume being x-rayed. On the basis of our results there is no likelihood of exceeding the limits of safety regulations even in a very busy operative environment, although a statistically increased incidence of thyroid cancer or a radiation-induced glaucoma is present. In vitro measurements with irradiation of a phantom resulted in the following recommendations: 1) fluoroscopy should be performed using the magnification-mechanism of the x-ray apparatus, 2) during lateral fluoroscopy the primary surgeon should be positioned close to the image intensifier. At least the surgeon should be familiar with the technique of closed reduction and instrumentation to reduce the duration of fluoroscopy which proved to be the most important factor for the amount of the radiation exposure.

Entities:  

Mesh:

Year:  1999        PMID: 10409910     DOI: 10.1007/s001130050420

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  5 in total

1.  Radiation dose in vertebroplasty.

Authors:  A Mehdizade; K O Lovblad; K E Wilhelm; T Somon; S G Wetzel; A D Kelekis; H Yilmaz; G Abdo; J B Martin; J M Viera; D A Rüfenacht
Journal:  Neuroradiology       Date:  2004-02-14       Impact factor: 2.804

2.  [Determining the femoral antetorsion angle with a fluoroscopy-based optoelectronic navigation system: a precision analysis].

Authors:  C Keil; J von Recum; L-P Nolte; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2008-02       Impact factor: 1.000

3.  [X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room].

Authors:  K Dresing
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

Review 4.  [Hazard assessment and occupational safety measures in surgery : Relevant knowledge on occupational medicine].

Authors:  S Darius; F Meyer; I Böckelmann
Journal:  Chirurg       Date:  2016-11       Impact factor: 0.955

5.  Radiation Dose to the Eye Lens Through Radiological Imaging Procedures at the Surgical Workplace During Trauma Surgery.

Authors:  Christian Apelmann; Birgitt Kowald; Nils Weinrich; Jens Dischinger; Albert Nienhaus; Klaus Seide; Heiko Martens; Christian Jürgens
Journal:  Int J Environ Res Public Health       Date:  2019-10-11       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.