Literature DB >> 10408106

Aqueous phase hexylchloroformate derivatization and solid phase microextraction: determination of benzoylecgonine in urine by gas chromatography-quadrupole ion trap mass spectrometry.

B J Hall1, A R Parikh, J S Brodbelt.   

Abstract

A derivatization/solid phase microextraction (SPME) method for the determination of benzoylecgonine in urine was developed. The derivatization is conducted directly in 1 mL of urine while sonicating for 3 min with 12 microL of hexyl chloroformate and 70 microL of a mixture containing acetonitrile:water:hexanol:2-dimethylaminopyridine (5:2:2:1 v/v), yielding benzoylecgonine hexyl ester (BHE) as the product. After the 3 min period, an aliquot of 250 microL is transferred to a vial for SPME. After the desired extraction time the 100 microns polydimethylsiloxane SPME fiber was transferred to the GC-MS for separation and analysis with a quadrupole ion trap mass spectrometer. The hexyl chloroformate derivatization and SPME procedures were optimized for compatibility and sensitivity. The method was found linear for 0.10 to 20.0 micrograms/mL (r2 = 0.999) of benzoylecgonine in urine using benzoylecgonine-d3 as an internal standard (1.5 micrograms/mL). Intra-day precisions were 8.8 and 6.8% RSD for 0.30 microgram/mL and 17 micrograms/mL benzoylecgonine standards in urine (n = 6), respectively. Inter-day precision (n = 3) were < or = 3.3% RSD, indicating good reproducibility. A detection limit of 0.03 microgram/mL (S/N = 3) was achieved, thus making the SPME method a simplified alternative to SPE for GC-MS confirmation after EMIT tests for benzoylecgonine which have a cutoff of 0.30 microgram/mL. Quantitative results by SPME and SPE of two clinical urine specimens known positive for cocaine by EMIT were in excellent agreement. Benzoylecgonine was detected by the derivatization/SPME method in 22 out of 22 other urine specimens known positive for cocaine.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10408106

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  2 in total

1.  Comparison of highly-fluorinated chloroformates as direct aqueous sample derivatizing agents for hydrophilic analytes and drinking-water disinfection by-products.

Authors:  Marco Vincenti; Stefano Biazzi; Nicoletta Ghiglione; Maria Carmen Valsania; Susan D Richardson
Journal:  J Am Soc Mass Spectrom       Date:  2005-03-29       Impact factor: 3.109

2.  Direct determination of urinary creatinine by reactive-thermal desorption-extractive electrospray-ion mobility-tandem mass spectrometry.

Authors:  Neil A Devenport; Daniel J Blenkhorn; Daniel J Weston; James C Reynolds; Colin S Creaser
Journal:  Anal Chem       Date:  2013-12-19       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.