Literature DB >> 10405743

Display modes for CT colonography. Part II. Blinded comparison of axial CT and virtual endoscopic and panoramic endoscopic volume-rendered studies.

C F Beaulieu1, R B Jeffrey, C Karadi, D S Paik, S Napel.   

Abstract

PURPOSE: To determine the sensitivity of radiologist observers for detecting colonic polyps by using three different data review (display) modes for computed tomographic (CT) colonography, or "virtual colonoscopy."
MATERIALS AND METHODS: CT colonographic data in a patient with a normal colon were used as base data for insertion of digitally synthesized polyps. Forty such polyps (3.5, 5, 7, and 10 mm in diameter) were randomly inserted in four copies of the base data. Axial CT studies, volume-rendered virtual endoscopic movies, and studies from a three-dimensional mode termed "panoramic endoscopy" were reviewed blindly and independently by two radiologists.
RESULTS: Detection improved with increasing polyp size. Trends in sensitivity were dependent on whether all inserted lesions or only visible lesions were considered, because modes differed in how completely the colonic surface was depicted. For both reviewers and all polyps 7 mm or larger, panoramic endoscopy resulted in significantly greater sensitivity (90%) than did virtual endoscopy (68%, P = .014). For visible lesions only, the sensitivities were 85%, 81%, and 60% for one reader and 65%, 62%, and 28% for the other for virtual endoscopy, panoramic endoscopy, and axial CT, respectively. Three-dimensional displays were more sensitive than two-dimensional displays (P < .05).
CONCLUSION: The sensitivity of panoramic endoscopy is higher than that of virtual endoscopy, because the former displays more of the colonic surface. Higher sensitivities for three-dimensional displays may justify the additional computation and review time.

Entities:  

Mesh:

Year:  1999        PMID: 10405743     DOI: 10.1148/radiology.212.1.r99jl17203

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

Review 1.  Improving the accuracy of CTC interpretation: computer-aided detection.

Authors:  Ronald M Summers
Journal:  Gastrointest Endosc Clin N Am       Date:  2010-04

Review 2.  Virtual endoscopy: current perspectives.

Authors:  Hajime Kuwayama; Mamoru Iimuro; Yoshinori Kitazumi; Gordon Luk
Journal:  J Gastroenterol       Date:  2002       Impact factor: 7.527

3.  A comparison of primary two- and three-dimensional methods to review CT colonography.

Authors:  Rogier E van Gelder; Jasper Florie; C Yung Nio; Sebastiaan Jensch; Steven W de Jager; Frans M Vos; Henk W Venema; Joep F Bartelsman; Johannes B Reitsma; Patrick M M Bossuyt; Johan S Laméris; Jaap Stoker
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 5.315

4.  Assessment of real-time 3D visualization for cardiothoracic diagnostic evaluation and surgery planning.

Authors:  Bradley M Hemminger; Paul L Molina; Thomas M Egan; Frank C Detterbeck; Keith E Muller; Christopher S Coffey; Joseph K T Lee
Journal:  J Digit Imaging       Date:  2005-06       Impact factor: 4.056

5.  CT colonography: comparison of a colon dissection display versus 3D endoluminal view for the detection of polyps.

Authors:  Markus S Juchems; Thorsten R Fleiter; Sandra Pauls; Stefan A Schmidt; Hans-Jürgen Brambs; Andrik J Aschoff
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

Review 6.  CT colonography: an update.

Authors:  Andrik J Aschoff; Andrea S Ernst; Hans-Juergen Brambs; Markus S Juchems
Journal:  Eur Radiol       Date:  2007-09-25       Impact factor: 5.315

7.  Panoramic endoluminal display with minimal image distortion using circumferential radial ray-casting for primary three-dimensional interpretation of CT colonography.

Authors:  Seung Soo Lee; Seong Ho Park; Jin Kook Kim; Namkug Kim; Jeongjin Lee; Beom Jin Park; Young Jun Kim; Min Woo Lee; Ah Young Kim; Hyun Kwon Ha
Journal:  Eur Radiol       Date:  2009-03-17       Impact factor: 5.315

8.  Uni- and bidirectional wide angle CT colonography: effect on missed areas, surface visualization, viewing time and polyp conspicuity.

Authors:  James E East; Brian P Saunders; Darren Boone; David Burling; Steve Halligan; Stuart A Taylor
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

  8 in total