Detection failures in spiral CT screening for lung cancer: analysis of CT findings.

R Kakinuma1, H Ohmatsu, M Kaneko, K Eguchi, T Naruke, K Nagai, Y Nishiwaki, A Suzuki, N Moriyama.   

Abstract

PURPOSE: To clarify the computed tomographic (CT) findings and the progression of minute lung cancers that were missed at initial spiral CT screening but were later detected.
MATERIALS AND METHODS: The findings from seven patients with lung cancer that was missed at the initial spiral CT screening were reviewed. Retrospective CT findings, time to detection, cell type, and pathologic stage were evaluated.
RESULTS: Minute lung cancers missed at early spiral CT included a nodule among the shadows of old tuberculosis (n = 2), a faint nodule with high attenuation in the center of the nodule (n = 1), an increase in attenuation just adjacent to an axial peripheral pulmonary vessel (n = 1) and adjacent to a craniocaudal peripheral pulmonary vessel (n = 1), and a minute faint nodule (n = 2). The time to detection ranged from 6 to 18 months. At pathologic examination, six cancers were stage I, and one was stage II.
CONCLUSION: Minute nodules of lung cancer that are near the threshold of detectability may be missed at spiral CT screening. It is important to examine noncalcified nodules with thin-section CT even when lesions from prior disease, such as those from old tuberculosis, exist and to evaluate the shadows of pulmonary vessels carefully. A follow-up examination is highly recommended.

Entities:  

Mesh:

Year:  1999        PMID: 10405721     DOI: 10.1148/radiology.212.1.r99jn1461

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  21 in total

1.  Epidemiological aspects of cancer screening in Germany.

Authors:  Nikolaus Becker
Journal:  J Cancer Res Clin Oncol       Date:  2003-10-14       Impact factor: 4.553

2.  Reply to commentary--'CT radiation dose reduction: can we do harm by doing good?'.

Authors:  Beverley Newman; Michael J Callahan
Journal:  Pediatr Radiol       Date:  2012-04

3.  Commercial CT scans: VOMIT victim of medical investigative technology.

Authors:  U Shaikh; Huw Lewis-Jones
Journal:  BMJ       Date:  2008-01-05

Review 4.  Computer-aided diagnosis of lung cancer and pulmonary embolism in computed tomography-a review.

Authors:  Heang-Ping Chan; Lubomir Hadjiiski; Chuan Zhou; Berkman Sahiner
Journal:  Acad Radiol       Date:  2008-05       Impact factor: 3.173

5.  Using the CT features to differentiate invasive pulmonary adenocarcinoma from pre-invasive lesion appearing as pure or mixed ground-glass nodules.

Authors:  J Liang; X-Q Xu; H Xu; M Yuan; W Zhang; Z-F Shi; T-F Yu
Journal:  Br J Radiol       Date:  2015-06-19       Impact factor: 3.039

Review 6.  Missed lung cancer: when, where, and why?

Authors:  Annemilia Del Ciello; Paola Franchi; Andrea Contegiacomo; Giuseppe Cicchetti; Lorenzo Bonomo; Anna Rita Larici
Journal:  Diagn Interv Radiol       Date:  2017 Mar-Apr       Impact factor: 2.630

7.  Lung abscess mimicking lung cancer developed around staples in a patient with permanent tracheostoma.

Authors:  Yui Watanabe; Masaya Aoki; Soichi Suzuki; Tadashi Umehara; Aya Harada; Kazuhiro Wakida; Toshiyuki Nagata; Kota Kariatsumari; Yoshihiro Nakamura; Masami Sato
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-04-23

8.  Comparing the performance of trained radiographers against experienced radiologists in the UK lung cancer screening (UKLS) trial.

Authors:  Arjun Nair; Natalie Gartland; Bruce Barton; Diane Jones; Leigh Clements; Nicholas J Screaton; John A Holemans; Stephen W Duffy; John K Field; David R Baldwin; David M Hansell; Anand Devaraj
Journal:  Br J Radiol       Date:  2016-07-27       Impact factor: 3.039

9.  Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening.

Authors:  Ernst Th Scholten; Nanda Horeweg; Harry J de Koning; Rozemarijn Vliegenthart; Matthijs Oudkerk; Willem P Th M Mali; Pim A de Jong
Journal:  Eur Radiol       Date:  2014-09-04       Impact factor: 5.315

10.  Automated lung nodule detection at low-dose CT: preliminary experience.

Authors:  Jin Mo Goo; Jeong Won Lee; Hyun Ju Lee; Seunghwan Kim; Jong Hyo Kim; Jung-Gi Im
Journal:  Korean J Radiol       Date:  2003 Oct-Dec       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.