Literature DB >> 10402302

A new thrombectomy catheter device (AngioJet) for the disruption of thrombi: An in vitro study.

P Stähr1, H J Rupprecht, T Voigtländer, F Post, M Otto, R Erbel, J Meyer.   

Abstract

In this study we examined a new thrombectomy catheter device. Different kinds of in vitro generated thrombi and cadaver thrombi were disrupted in test tubes. The mean disruption rate (and disruption time for 1 g of thrombus) was 225 +/- 65 mg/sec (5 +/- 2 sec) for whole-blood, 117 +/- 60 mg/sec (12 +/- 9 sec) for fibrin, 41 +/- 18 mg/sec (30 +/- 18 sec) for mixed, 70 +/- 42 mg/sec (17 +/- 5 sec) for unorganized, 45 +/- 8 mg/sec (22 +/- 4 sec) for partly, and 5 +/- 1 mg/sec (216 +/- 29 sec) for completely organized cadaver thrombi (P < 0.05). More than 99% of fragmented particles of whole-blood thrombi were 0-12 microm in diameter. The particle size of fibrin, mixed, and cadaver thrombi was similar, with 25%-40% of particles between 0-12 microm, 55%-71% >12-24 microm, and 2%-7% >24 microm. The device may be effectively used in the therapy of massive pulmonary embolism or acute peripheral and coronary artery syndromes when medical thrombolysis is contraindicated and organization of thrombus is absent. Further studies need to be performed to investigate the potential effects of particle microembolization. Cathet. Cardiovasc. Intervent. 47:381-389, 1999. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10402302     DOI: 10.1002/(sici)1522-726x(199907)47:3<381::aid-ccd29>3.0.co;2-#

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  6 in total

1.  Percutaneous rheolytic mechanical thrombectomy in thrombosed direct intrahepatic portosystemic shunt: Report of two cases.

Authors:  Dimitrios Tsetis; Elias Kehagias; Dimitrios Samonakis; Elias Kouroumalis; Adam Hatzidakis
Journal:  Interv Med Appl Sci       Date:  2015-12

Review 2.  For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy.

Authors:  Kenneth B Bader; Eli Vlaisavljevich; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2019-03-26       Impact factor: 2.998

3.  Treatment of vertebrobasilar occlusion by using a coronary waterjet thrombectomy device: a pilot study.

Authors:  Thomas E Mayer; Gerhard F Hamann; Gernot Schulte-Altedorneburg; Hartmut Brückmann
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

4.  Experimental model of large pulmonary embolism employing controlled release of subacute caval thrombus in swine.

Authors:  Israel M Barbash; William H Schenke; Majdi Halabi; Kanishka Ratnayaka; Anthony Z Faranesh; Ozgur Kocaturk; Robert J Lederman
Journal:  J Vasc Interv Radiol       Date:  2011-07-28       Impact factor: 3.464

5.  Experimental Evaluation of the Effectiveness of Aspiration-Based Techniques to Treat Different Types of Acute Thromboembolic Occlusions in the Femoropopliteal Vascular System Using an In Vitro Flow Model.

Authors:  Schekeb Aludin; Philipp Jost Schäfer; Christoph Borzikowsky; Olav Jansen; Julian Pfarr; Rouven Berndt; René Rusch; Jens Trentmann
Journal:  Cardiovasc Intervent Radiol       Date:  2021-12-17       Impact factor: 2.740

6.  Angiojet System Used in the Treatment of Submassive Pulmonary Embolism: A Case Report of Two Patients.

Authors:  Jinbo Liu; Tianrun Li; Wei Huang; Na Zhao; Hongwei Zhao; Hongyu Wang
Journal:  Case Rep Vasc Med       Date:  2022-08-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.