Feasibility study: transesophageal echocardiography with a 10F (3.2-mm), multifrequency (5.5- to 10-MHz) ultrasound catheter in a small rabbit model.

C J Bruce1, D L Packer, P W O'Leary, J B Seward.   

Abstract

Transesophageal echocardiography (TEE) is useful in children with congenital heart defects. However, because of available probe size (>/=7 mm diameter), its use is limited to patients weighing more than 3 kg. The aim of this study was to determine the feasibility of TEE in a small animal model by using a 10F (3.2-mm) intravascular ultrasound tipped catheter with a monoplane (longitudinal) 5.5- to 10-MHz phased vector array transducer. Ten New Zealand White rabbits (400 to 3400 g; mean 1580 g) underwent TEE. With animals under general sedation, the probe was blindly introduced into the esophagus. All intracardiac and extracardiac structures were examined, and the images were stored and independently reviewed. All pertinent intracardiac and extracardiac structures were identified except in the 3 smallest rabbits (400 to 600 g). Doppler hemodynamics and color Doppler were possible in each animal. Frequency agility (5.5 to 10 MHz) facilitated optimization of image resolution and penetration. Certain transgastric, 4-chamber, and short-axis views were limited because of the monoplane array. No overt adverse effects were associated with the procedure. Diagnostic TEE can be performed in a small animal model with a 10F, 5.5- to 10-MHz phased vector array ultrasound catheter. Our study suggests that this system has potential in performing diagnostic TEE safely in small, even premature, neonates.

Entities:  

Mesh:

Year:  1999        PMID: 10398919     DOI: 10.1016/s0894-7317(99)70008-8

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

1.  Transoesophageal ultrasonography: a new approach to imaging the thoracic aorta.

Authors:  J B Chambers; P R Taylor; J F Reidy; C Woods; S J Carter; T S Padayachee
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

Review 2.  Intracardiac echocardiography in congenital heart disease.

Authors:  Piers C A Barker
Journal:  J Cardiovasc Transl Res       Date:  2009-01-23       Impact factor: 4.132

3.  Shape analysis of the prostate: establishing imaging specifications for the design of a transurethral imaging device for prostate brachytherapy guidance.

Authors:  David R Holmes; Brian J Davis; Christopher C Goulet; Torrence M Wilson; Lance A Mynderse; Keith M Furutani; Jon J Camp; Richard A Robb
Journal:  Brachytherapy       Date:  2014-06-21       Impact factor: 2.362

4.  Prospective evaluation of complications associated with transesophageal echocardiography in dogs with congenital heart disease.

Authors:  Caitlin H Stoner; Ashley B Saunders; Johanna C Heseltine; Audrey K Cook; Jonathan A Lidbury
Journal:  J Vet Intern Med       Date:  2022-01-08       Impact factor: 3.333

5.  Cardiac impairment evaluated by transesophageal echocardiography and invasive measurements in rats undergoing sinoaortic denervation.

Authors:  Raquel A Sirvente; Maria C Irigoyen; Leandro E Souza; Cristiano Mostarda; Raquel N La Fuente; Georgia O Candido; Pamella R M Souza; Alessandra Medeiros; Charles Mady; Vera M C Salemi
Journal:  PLoS One       Date:  2014-05-14       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.