Literature DB >> 10398821

Semi-quantitative ventilation/perfusion scintigraphy and single-photon emission tomography for evaluation of lung volume reduction surgery candidates: description and prediction of clinical outcome.

D A Jamadar1, E A Kazerooni, F J Martinez, R L Wahl.   

Abstract

Ventilation/perfusion scans with single-photon emission tomography (SPET) were reviewed to determine their usefulness in the evaluation of lung volume reduction surgery (LVRS) candidates, and as a predictor of outcome after surgery. Fifty consecutive planar ventilation (99mTc-DTPA aerosol) and perfusion (99mTc-MAA) scans with perfusion SPET of patients evaluated for LVRS were retrospectively reviewed. Technical quality and the severity and extent of radiotracer defects in the upper and lower halves of the lungs were scored from visual inspection of planar scans and SPET data separately. An emphysema index (EI) (extent x severity) for the upper and lower halves of the lung, and an EI ratio for upper to lower lung were calculated for both planar and SPET scans. The ratios were compared with post-LVRS outcomes, 3, 6 and 12 months after surgery. All perfusion and SPET images were technically adequate. Forty-six percent of ventilation scans were not technically adequate due to central airway tracer deposition. Severity, extent, EI scores and EI ratios between perfusion and SPET were in good agreement (r = 0.52-0.68). The mean perfusion EI ratio was significantly different between the 30 patients undergoing biapical LVRS and the 17 patients excluded from LVRS (3.3+/-1.8 versus 1.2+/-0.7; P<0.0001), in keeping with the anatomic distribution of emphysema by which patients were selected for surgery by computed tomography (CT). The perfusion EI ratio correlated moderately with the change in FEV1 at 3 months (r = 0.37, P = 0.04), 6 months (r = 0.36, P = 0.05), and 12 months (r = 0.42, P = 0.03), and the transition dyspnea index at 6 months (r = 0.48, P = 0.014) after LVRS. It is concluded that patients selected to undergo LVRS have more severe and extensive apical perfusion deficits than patients not selected for LVRS, based on CT determination. SPET after aerosol V/Q imaging does not add significantly to planar perfusion scans. Aerosol DTPA ventilation scans are not consistently useful. Perfusion lung scanning may be useful in selecting patients with successful outcomes after LVRS.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10398821     DOI: 10.1007/s002590050444

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  6 in total

1.  Perfusion scintigraphy and patient selection for lung volume reduction surgery.

Authors:  Divay Chandra; David A Lipson; Eric A Hoffman; John Hansen-Flaschen; Frank C Sciurba; Malcolm M Decamp; John J Reilly; George R Washko
Journal:  Am J Respir Crit Care Med       Date:  2010-06-10       Impact factor: 21.405

2.  Hyperpolarized Helium-3 MRI of exercise-induced bronchoconstriction during challenge and therapy.

Authors:  Stanley J Kruger; David J Niles; Bernard Dardzinski; Amy Harman; Nizar N Jarjour; Marcella Ruddy; Scott K Nagle; Christopher J Francois; Ronald L Sorkness; Ryan M Burton; Alejandro Munoz del Rio; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2013-09-04       Impact factor: 4.813

3.  Oxygen-enhanced 3D radial ultrashort echo time magnetic resonance imaging in the healthy human lung.

Authors:  Stanley J Kruger; Sean B Fain; Kevin M Johnson; Robert V Cadman; Scott K Nagle
Journal:  NMR Biomed       Date:  2014-07-02       Impact factor: 4.044

4.  Hyperpolarized 3He MRI and 81mKr SPECT in chronic obstructive pulmonary disease.

Authors:  Trine Stavngaard; Lise Vejby Søgaard; Jann Mortensen; Lars G Hanson; Jörg Schmiedeskamp; Anne Kiil Berthelsen; Asger Dirksen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-11-20       Impact factor: 9.236

5.  Complication and lung function impairment prediction using perfusion and computed tomography air trapping (CLIPPCAIR): protocol for the development and validation of a novel multivariable model for the prediction of post-resection lung function.

Authors:  Carey Meredith Suehs; Laurence Solovei; Kheira Hireche; Isabelle Vachier; Denis Mariano Goulart; Lucie Gamon; Jérémy Charriot; Isabelle Serre; Nicolas Molinari; Arnaud Bourdin; Sébastien Bommart
Journal:  Ann Transl Med       Date:  2021-07

6.  Assessment of lobar perfusion in smokers according to the presence and severity of emphysema: preliminary experience with dual-energy CT angiography.

Authors:  Vittorio Pansini; Martine Remy-Jardin; Jean-Baptiste Faivre; Bernhard Schmidt; Alexis Dejardin-Bothelo; Thierry Perez; Valérie Delannoy; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315