Literature DB >> 10398032

Interaction between carbon composites and bone after intrabone implantation.

M Lewandowska-Szumieł1, J Komender, J Chłopek.   

Abstract

Candidate carbon fiber reinforced carbon (CFRC) porous implant materials were evaluated for tissue compatibility in a rat model. Six different CFRCs of constant pore size (about 30 microm) were fabricated that had 9, 12, and 17% porosity with 2-nm3 matrix crystallites and 6, 12, and 20% at 25 nm3. They were implanted as femoral transverse diaphyseal pins that were 1.5 mm in diameter. At 5 and 45 weeks, implant and bone histologic specimens were evaluated histologically and by a scanning electron microscope and an electron microprobe. Also, regional lymph nodes and spleens were examined. By 45 weeks, direct implant-bone contact was observed over most of the interface in most specimens. At the implant surface, there was partial replacement of CFRC with host tissue. However, the microprobe showed that the implant-bone interface was chemically abrupt with no cross-diffusion of ionic species. Besides the surface effects, there was partial filling of the implant pores with tissue, including bone organized de novo deep within. This was observed histologically and confirmed by microprobe. Lymph nodes and spleens were histologically normal, and no carbon particles were found. None of the results were influenced by porosity or matrix crystallite size over the ranges studied. In summary, these porous CFRCs are partially degraded when in contact with bone and appear substantially tissue compatible. They may be useful as scaffolds for regrowth of bone. Copyright 1999 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10398032     DOI: 10.1002/(sici)1097-4636(1999)48:3<289::aid-jbm12>3.0.co;2-l

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  3 in total

Review 1.  Biomaterials in orthopaedics.

Authors:  M Navarro; A Michiardi; O Castaño; J A Planell
Journal:  J R Soc Interface       Date:  2008-10-06       Impact factor: 4.118

2.  SEM and EDS investigation of a pyrolytic carbon covered C/C composite maxillofacial implant retrieved from the human body after 8 years.

Authors:  Béla Sebők; Gábor Kiss; Péter J Szabó; Dániel Rigler; Milán L Molnár; Gábor Dobos; Ferenc Réti; Hajnal Szőcs; Arpád F Joób; Sándor Bogdán; György Szabó
Journal:  J Mater Sci Mater Med       Date:  2012-12-30       Impact factor: 3.896

3.  Biocompatibility and Application of Carbon Fibers in Heart Valve Tissue Engineering.

Authors:  Yuan-Tsan Tseng; Nabil F Grace; Heba Aguib; Padmini Sarathchandra; Ann McCormack; Ahmed Ebeid; Nairouz Shehata; Mohamed Nagy; Hussam El-Nashar; Magdi H Yacoub; Adrian Chester; Najma Latif
Journal:  Front Cardiovasc Med       Date:  2021-12-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.