Aorto-right ventricular fistula: a late complication of aortic valve replacement.

D Roy1, S Saba, I Grinberg, M Zughaib, M Sakwa, P Clancy, G McKendrick.   

Abstract

We report the case of a patient who was found to have an aorto-right ventricular fistula 17 years after receiving a Björk-Shiley prosthetic aortic valve. A pseudoaneurysm had formed at the aortotomy suture line, and it had extended into the interventricular septum and had eventually opened into the right ventricle. Using transesophageal echocardiography, we identified the defect in the ascending aorta, and a left-to-right shunt. Aortography was used to confirm these findings. The pseudoaneurysm was successfully resected and the ascending aorta was replaced with a Dacron graft. To the best of our knowledge, no similar late complication of aortic valve replacement has been reported in the medical literature.

Entities:  

Mesh:

Year:  1999        PMID: 10397439      PMCID: PMC325620     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  8 in total

1.  Cardiac pathology after valve replacement with a tilting disc prosthesis (Björk-Shiley type). A study of 46 necropsy patients and 49 Björk-Shiley prostheses.

Authors:  W C Roberts; W J Hammer
Journal:  Am J Cardiol       Date:  1976-06       Impact factor: 2.778

2.  Aortographic follow-up in patients with the Björk-Shiley aortic disc valve prosthesis.

Authors:  V O Björk; A Henze; M Jereb
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1973

3.  Aortic sinus aneurysm. Report of an unusual case.

Authors:  V O Björk; O Edhag
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1972

4.  False aneurysm of the ascending aorta following aortic valve replacement.

Authors:  B Albat; P F Leclercq; P MessnerPellenc; E Missov; A Thevenet
Journal:  J Heart Valve Dis       Date:  1994-03

5.  Complications of cardiac valve replacement: characteristic abnormalities of prostheses pertaining to any or specific site.

Authors:  W C Roberts
Journal:  Am Heart J       Date:  1982-01       Impact factor: 4.749

6.  Long-term follow-up of isolated replacement of the aortic or mitral valve with the Starr-Edwards prosthesis.

Authors:  D A Barnhorst; H A Oxman; D C Connolly; J R Pluth; G K Danielson; R B Wallace; D C McGoon
Journal:  Am J Cardiol       Date:  1975-02       Impact factor: 2.778

7.  Pseudoaneurysm of the ascending aorta following cardiac surgery.

Authors:  K L Sullivan; R M Steiner; S N Smullens; L Griska; S G Meister
Journal:  Chest       Date:  1988-01       Impact factor: 9.410

Review 8.  Role of transesophageal echocardiography in the diagnosis and management of prosthetic valve thrombosis.

Authors:  V Dzavik; G Cohen; K L Chan
Journal:  J Am Coll Cardiol       Date:  1991-12       Impact factor: 24.094

  8 in total
  5 in total

1.  Aorto-right ventricular fistula after percutaneous aortic valve implantation of a CoreValve prosthesis.

Authors:  Antonio J Muñoz-García; Isabel Rodríguez-Bailón; Juan H Alonso Briales; Manuel Jiménez Navarro; José M Hernández García; Eduardo de Teresa-Galván
Journal:  Tex Heart Inst J       Date:  2011

2.  Aorto-right atrial fistula: Late complication of tricuspid valve infective endocarditis.

Authors:  Pedro A Villablanca; Shashvat Sukhal; Oscar Maitas; Afiachuukwu Onuegbu; Juan M Muñoz-Peña; Ajay Joseph; Carlos Requena; Divyanshu Mohananey
Journal:  World J Cardiol       Date:  2014-10-26

3.  Aortocavitary fistula as a complication of infective endocarditis and subsequent complete heart block in a patient with severe anemia.

Authors:  Jose N Galeas; Irving E Perez; Pedro A Villablanca; Harjit Chahal; Robert Jackson; Cynthia C Taub
Journal:  J Community Hosp Intern Med Perspect       Date:  2015-12-11

4.  Aorto-Right Ventricular Shunt after TAVR: Rare Complication of Common Procedure.

Authors:  Abdelkader Almanfi; Ahmad Qurie; Neil Strickman
Journal:  Case Rep Cardiol       Date:  2017-09-28

5.  Role of Echocardiography in the Diagnosis of Aorto-Right Ventricular Fistula: A Rare Complication of Surgical Aortic Valve Replacement Successfully Closed by Bovine Pericardial Patch.

Authors:  Jamal Janjua; Michael A Witcik; Aiman Riaz; Raju G Ailiani
Journal:  CASE (Phila)       Date:  2017-11-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.